background image

 

••••  www.master-bilt.com  •  Pg. 5 •••• 

 

ELECTRICAL REQUIREMENTS 

 

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a 
standard 3-prong (grounding) NEMA 5-15R type wall outlet to minimize the possibility of electric 
shock hazard from this appliance. 

 

The use of extension cords is not permitted and will void the warranty. 

 

 

Model

 

Voltage 

(V)

 

Current 

(A)

 

Circuit 

Required (A)

 

BGR15

 

120

 

5.7

 

15

 

 

Before connecting your equipment, check that the electrical data on the data plate match your electrical 
output. 

 

IMPORTANT NOTICE: P

LUG THE EQUIPMENT INDEPENDENTLY TO A LOAD CENTER WITH AN 

APPROPRIATE CIRCUIT BREAKER ACCORDING TO THE NAMEPLATE AMPS

 

 

POSITIONING SHELVES 

 

The  shelves  and  holders  have  been  fixed  to  the  inside  floor  of  
the unit to prevent their loss during transportation. 

 

Insert the shelf clips in the pilaster notches making sure they are 
at the same level such that the shelves remain horizontal. 

 

IMPORTANT:  The  products  on  each  shelf  must  leave  three  to 
five  centimeters  of  free  clearance  between  them  and  the  next 
shelf in order to allow proper air circulation. 

 

Содержание BGR15

Страница 1: ...North New Albany MS 38652 800 647 1284 Fax 866 882 7629 INSTALLATION AND OPERATION MANUAL BGR15 Congratulations You have just purchased the finest commercial refrigeration available 6 16 Rev A 57 025...

Страница 2: ...Master Bilt cooler when installed correctly and properly maintained will give you many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL W...

Страница 3: ...pt in storage it is suggested to keep it in its original packing In case you need your equipment to be inactive for a long period of time after being used verify that it has been unplugged After clean...

Страница 4: ...of the refrigerating system it is very important to leave at least 10 cm 4 of free space both at the sides and back to allow proper air circulation The location of the cooler must be kept away from s...

Страница 5: ...heck that the electrical data on the data plate match your electrical output IMPORTANT NOTICE PLUG THE EQUIPMENT INDEPENDENTLY TO A LOAD CENTER WITH AN APPROPRIATE CIRCUIT BREAKER ACCORDING TO THE NAM...

Страница 6: ...eration of the unit based on the temperature of the air discharging from the evaporator at the back of the unit In order to achieve the desired product temperature the electronic control is factory ad...

Страница 7: ...ATION EVAPORATOR TRAY When the equipment operates condensed water from the environment is collected on the evaporator During each off cycle the water drains to the evaporator tray located at the botto...

Страница 8: ...unit Do not allow the electronic control to be adjusted by customers or unqualified personnel For any adjustment you must contact your distributor Verify that the hot air stream from the condenser tow...

Страница 9: ...rts CLEANING THE CONDENSER COIL IMPORTANT WARRANTY INFORMATION Condensers accumulate dirt and require regular cleaning Dirty condensers result in compressor failure product loss and lost sales which a...

Страница 10: ...t immediately contact your distributor specifying the kind of problem and clearly indicating the equipment model and serial number If replacing parts is required do it through your distributor WARNING...

Отзывы: