• Do not perform a voltage test using the 10A input jack.
• Always be careful when working with voltages above 60V dc  or 
30V ac rms. Keep fingers behind the probe barriers when making 
voltage measurements.
• When connecting the test leads to a measurement circuit,
 connect the common lead first, then the live lead. Reverse when 
disconnecting.
• Disconnect leads from circuit before switching functions/ranges.
• Disconnect leads from circuit before testing transistors.
• Turn off power to circuit and discharge all capacitors before
 making resistance, continuity or diode measurements.
• Before making current measurements, turn off power to the
circuit, break the circuit, connect the leads in series across the 
break, then turn the power back on for measurement.
• When the “      ”symbol appears, replace the batteries to avoid 
incorrect readings.

1.1 

 

Safety Guidelines

To ensure safe usage of this instrument, please read the 
following carefully:

1.1.1 Precautions

• All the instrument to warm up for 30 sec. before measurement.
• Inspect the case before use.  Check for cracks in the casing 
and the insulation around the input sockets.
• Only use the test leads provided with the meter.If leads are
 damaged or need to be replaced, use similar leads with 
matching specifications.
• Ensure the meter works properly by testing a known voltage
 source first.If not working properly, the protective equipment 
may be damaged; have the meter serviced before using.
• Do not place meter in a strong magnetic field; this may cause
 false readings.
• Do not place the meter in any environment with high pressure, 
high temperature, dust, explosive gas or vapor.

1.Introduction

This digital multimeter can measure AC/DC voltage, 
AC/DC current, resistance, diode, the voltage of battery,
 temperature. The meter complies with international 
safety standards EN61010-1,61010-2-030, 61010-2-033, 
CAT III 600V and pollution degree of 2.
Read all instructions carefully before using the meter and 
follow all relevant safety standards.
To ensure safe usage of this instrument, please read the 
following carefully:

WARNING

The  special  attention  should  be  paid  when  using  the  meter 
because  the  improper  usage  may  cause  electric  shock  and 
damage  the  meter  .The  safety  measures  in  common  safety 
regulations and operating instruction should be complied with 
when  using.  In  order  to  make  fully  use  of  its  functions  and 
ensure  safe  operations  please  comply  with  the  usage  in  this 
section carefully.

• Make sure the test leads are in the correct input jacks  before
 measurement.
• Choose the highest range when the value to be measured is 
unknown beforehand.
• Never exceed the protection limit values indicated in the
 specifications for each range of measurement.

1.1.2 Safety Symbols 

Fuse must be replaced as per the specification 
herein.

Note-Important safety information, refer to the 

instruction manual.

 Earth (ground) TERMINAL

Caution, possibility of electric shock

Equipment protected throughout by double 
insulation or reinforced insulation.

01

Содержание MS8321B

Страница 1: ...MS8321B Digital Multimeter ...

Страница 2: ...nes 1 2 6 Automatic Power Off 5 3 2 Technical Specifications 7 3 2 1 DC Voltage 7 3 2 2 AC Voltage 7 3 2 4 AC Current 8 3 2 5 Resistance 9 3 2 6 Continuity Diode Test 9 3 2 3 DC Current 8 3 2 7 Temperature Test 9 4 Operating Instructions 10 4 1 DC AC Voltage 10 4 2 Resistance 10 4 3 DC AC Current 11 4 4 Diodes 12 4 5 Continuity 12 4 6 Temperature 13 5 Maintenance 14 5 1 Cleaning the Meter 14 4 7 B...

Страница 3: ...ged have the meter serviced before using Do not place meter in a strong magnetic field this may cause false readings Do not place the meter in any environment with high pressure high temperature dust explosive gas or vapor 1 Introduction This digital multimeter can measure AC DC voltage AC DC current resistance diode the voltage of battery temperature The meter complies with international safety s...

Страница 4: ...the manual F1 400mA 600V and F2 10A 600V Before opening the case always disconnect test leads from all energized circuits Never use the meter unless the back cover is in place and fastened securely If any abnormality is observed stop using the meter and send it in for repair If the meter is not going to be used for an extended period of time remove the batteries and avoid storing in a hot humid en...

Страница 5: ... x36 H mm Weight approx 220g including battery 05 06 2 2 Display 3 digit 15mm LCD display 2 3 Hold Button Press to keep the current reading on the display Press the button again to return to normal display 2 4 Rotary Switch The rotary switch is used to switch between functions ranges Functions are voltage current resistance diode continuity and transistor gain 2 5 Input Jacks VΩmA C F voltage resi...

Страница 6: ...ponding 3 2 3 DC Current Resolution Accuracy 2mA 1µA 10µA 10mA 20mA 10A 2 0 of reading 5 digits Measuring range 1 0 of reading 3 digits Overload Protection F1 400mA 600V F2 10A 600V Max Input Current mA 200mA DC or AC rms 10A continuous do not exceed 15 sec 3 2 4 AC Current Resolution Accuracy 10µA 10mA 20mA 10A 3 0 of reading 10 digits Measuring range 1 2 of reading 5 digits Overload Protection F...

Страница 7: ...it under test Read the measured voltage on the display When measuring DC voltage the display will show the polarity of the red lead If the display only shows 1 it indicates the input exceeds the selected range Move the rotary switch to a higher range 4 Operating Instructions 4 1 DC AC Voltage Warning Max input voltage 600V DC or AC rms 200mV range is 250V DC or AC rms Do not exceed the protection ...

Страница 8: ...isplay only shows 1 it indicates the input exceeds the selected range Move the rotary switch to a higher range 4 4 Diodes Turn the rotary switch to the position Connect the red test lead to the input jack and the black test lead to the COM jack Connect the red lead to the anode and the black lead to the cathode of the diode The meter displays the forward voltage drop of the diode If the leads are ...

Страница 9: ...12V 9V 1 5V Connect the red test lead to the input jack and the black test lead to the COM jack Connect the red lead to the positive terminal and the black lead to the negative terminal of the battery under test Read the voltage value of the battery on the display 5 Maintenance 5 1 Cleaning the Meter Warning Before opening the back cover turn off the meter and disconnect test leads from any circui...

Страница 10: ...s F1 400mA 600V F2 10A 600V The replacement should be of the same specification 3 The battery for this multimeter is 9V NEDA 1604 or 6F22 The replacement should be of the same specification 4 Don t put the instrument into use until the rear cover is screwed after replacing battery or fuse To avoid electric shock make sure the probes are disconnected from the measured circuit before removing the re...