5. Specifications

5.1

 

General Specifications

When battery voltage drops below 
normal operating voltage,“       ”is 
shown on the display

Polarity Indication

Display automatically displays “-“

Function

Range

Safety Rating

CAT III 600V,  pollution degree: II

Operating Altitude

<2000m

Operating Temperature/
Humidity

0~40°C, <80% RH

Storage Temperature/
Humidity

-10~60°C, <70% RH, remove battery

Max. Input between 
terminals and earth 
ground

600V DC or AC rms

Fuse Protection

µA/mA ranges: FF 400mA H 600V
10A range: FF 10A H 600V

Sample Rate

Approx. 3 times/sec.

Display

3 ½ digit LCD display

Overload Indication

Display shows “OL”

Low Battery Indication

Temperature 
coefficient

0.1xaccuracy/°C (>18°C or <28°C)

5.2

 

Technical Specifications

Accuracy: ±(% of r digits) at 18°C~28°C with a 
relative humidity of <80%; guaranteed for a period of 
one year.

Resolution

Accuracy

2V

20V

0.01V

0.001

V

5.2.2 AC Voltage

Measuring range

±(0.5% of r5 digits)

5.2.1 DC Voltage

Input impedance: 10M

Ω

Max. input voltage: 600V DC or AC rms.

Resolution

Accuracy

200mV

2V

0.1V

0.001V

0.1

mV

0.01V

1V

20V

200V

600V

±(0.8% of r3 digits)

Measuring range

±(0.5% of r3 digits)

200V

600V

1V

0.1

V

±(1.0% of r5 digits)

Input impedance: 10M

Ω

Max. input voltage: 600V DC or AC rms.
Frequency Response: 40~400Hz, sine wave rms 
(avg. response)

Power Supply

DC 9V, NEDA 1604 or 6F22

Size(LxWxH)

148x73.5x50mm

weight

about 232g

Содержание MS8238C

Страница 1: ...al Digital Multimeter CAT III 600V MS8238C DIGITAL MULTIMETER Autorange Auto power off 9V 1 5V 12V FUNC HOLD RAN NCV 600V CAT III mA μA V TEMP mAμAV TEMP COM MAX 30 sec every 15 min MAX FUSED 10A MAX 200mA FUSED MAX 600V ...

Страница 2: ...7 4 1 AC DC voltage measurement 7 4 2 AC DC current measurementrent 7 3 4 Auto Power Off Function 6 5 Specifications 11 5 1 General Specifications 11 5 2 Technical Specifications 12 4 3 Resistance measurement 8 4 4 Continuity measurement 9 4 5 Diode test 9 4 6 Battery test 10 4 7 Temperature measurement 10 6 Maintenance 15 6 1 General Maintenance 15 6 3 Replacing the Probe 16 6 2 Replacing the Bat...

Страница 3: ... source first If not working properly the protective equipment may be damaged have the meter serviced before using Never measure voltages that may exceed the protection limit indicated on the meter Always be careful when working with voltages above 60V DC or 30V AC rms Keep fingers behind the probe barriers when making voltage measurements Make sure the test leads are in the correct input jacks be...

Страница 4: ...mediately A protective device may be damaged If there is any doubt please have the meter inspected by a qualified technician 2 3 Electrical Symbols AC DC Both direct and Alternating Current Important safety information High voltage with danger Ground Double Insulation Class II safety equipment Fuse must be replaced as per the specification herein Accord with the related EU laws and regulations AC ...

Страница 5: ... the non contact voltage detection Hold the meter up to a voltage source and the buzzer will sound and the NCV indicator will light up if voltage is detected Release the NCV button to stop NCV detection 3 4 Auto Power Off Function turn itself off To turn the meter back on press any button or turn the rotary switch to any position To deactivate the auto power off function hold down HOLD when turnin...

Страница 6: ... test lead to either the input or 10A jack and the black lead to the COM jack Break the circuit and connect the leads in series with the circuit black lead on the lower voltage side Turn circuit power on and read the measurement on the display If OL is display it means the measurement has exceeded the current range Move the rotary switch to a higher range 4 3 Resistance measurement discharge Set t...

Страница 7: ...ill display OL if the connection is reversed WARNING To prevent injury or damage to the meter turn off power to circuit and discharge all capacitors fully before making diode measurements 4 6 Battery test Connect the red test lead to the input jack and the black lead to the COM jack Connect the red test lead to the positive end and the black lead to the negative end of the battery and read the mea...

Страница 8: ...dication Display shows OL Low Battery Indication Temperature coefficient 0 1xaccuracy C 18 C or 28 C 5 2 Technical Specifications Accuracy of reading digits at 18 C 28 C with a relative humidity of 80 guaranteed for a period of one year Resolution Accuracy 2V 20V 0 01V 0 001V 5 2 2 AC Voltage Measuring range 0 5 of reading 5 digits 5 2 1 DC Voltage Input impedance 10MΩ Max input voltage 600V DC or...

Страница 9: ...AC rms Display shows forward voltage drop Function Description Resolution 1 5V Diode Test Rang 1mV 20mA 200mA 10A 0 01mA 0 1mA 10mA Overload protection mA jack FF 400mA H 600V fuse 10A jack FF 10A H 600V fuse Max input current mA jack 200mA DC 10A jack 10A DC When measuring current exceeding 2A do not measure for longer than 2 minutes continuously Wait 10 minutes to continue measurement 5 2 7 AC C...

Страница 10: ... C 1 C 1 F 4 1382 F Position 2 0 of reading 2 digits Overload protection FF 400mA H 600V fuse 5 2 9 Battery Test Resolution Accuracy 12V 0 01V 0 01V 9V Position 0 8 of reading 7 digits 1 5V 0 001V 0 8 of reading 7 digits 3 0 of reading 5 digits Overload protection FF 400mA H 600V fuse 2 0 of reading 4 digits 6 2 Replacing the Battery and Fuses 6 3 Replacing the Probe 1 Under normal conditions it i...

Страница 11: ...R 00 05 1568 ...

Отзывы: