![Mastech MS8040 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/mastech/ms8040/ms8040_manual_1736118034.webp)
BENCH MODEL MULTIMETER
10A
1mA
±(0.5% +15)
Note:
Above accuracies can be guaranteed within the full range.
Resistance Accuracy
Range
Accuracy
200Ω
±(0.1% +10)
2KΩ
±(0.1% +10)
20KΩ
±(0.1% +5)
200KΩ
±(0.1% +5)
2MΩ
±(0.1% +10)
20MΩ
±(0.5% +10)
200MΩ
±(2 % +10)
Notes:
1. Above accuracies can be guaranteed within the full range.
2.Accuracy for diode and continuity are unspecified.In Continuity Test Mode,the bluzzer will beeper if the
measure value lower than 20Ω,may or not beep if the measure value between 20Ωand 50 Ω.not beep when the
measure value higher than 50Ω
Capacitance Accuracy
Range
Resolution
Accuracy
20nF
0.01nF
±(1.2% +30)
200nF
0.1nF
±(1.2% +30)
2μF
1nF
±(1.2% +30)
20μF
10nF
±(1.2% +30)
31