Safety Information

1,TO REDUCE THE RISK OF FIRE, ELECTRICAL 
   SHOCK, DAMAGE TO THE INSTRUMENT OR 
   PERSONAL INJURY, PLEASE FOLLOW THE 
   SAFETY INSTRUCTIONS DESCRIBED IN THE 
   USER MANUAL.
2,TO ENSURE SAFE OPERATION AND LIFE OF 
   THE METER, DO NOT PLACE THE METER IN 
   ANY ENVIRONMENT WITH HIGH PRESSURE, 
   HIGH TEMPERATURE, DUST, EXPLOSIVE GAS 
   OR VAPOR. 

WARNING:

01

02

LIMITED WARRANTY AND LIMITATION OF LIABILITY

This instrument from Mastech Tools Inc. will be free from 
defects in workmanship and material for three years from 
the date of original purchase.  This warranty does not 
cover defects resulting from damage caused by the user 
such as drops, neglect, misuse, unauthorized alteration, 
usage outside of specified conditions, contamination, or 
improper repair/maintenance.  To receive service on the 
instrument if it becomes necessary during the warranty 
period, contact your nearest Mastech authorized service 
center at 8190-1600 or visit www.p-mastech.com 
to obtain a return authorization .  
A return authorization is necessary before returning any 
instrument to Mastech; no service will be provided without 
a return authorization.The user is responsible for properly 
packing the unit and charges such as shipping, freight 
and insurance charges.The extent of Mastech's liability is 
limited solely to the repair/replacement of the instrument.  
The above warranty in its entirety is inclusive and no other 
warranties, written or oral, are expressed or implied.

Safety Symbols

01

Note-Important safety information,

refer to the instruction manual.

Conforms to UL STD. 61010-1, 61010-2-032,
61010-2-033; Certified to CSA STD C22.2 
NO. 61010-1, IEC STD.61010-2-032,
61010-2-033

Complies with European (EU) safety 
standards

 Earth (ground) TERMINAL

Caution when testing on live conductors.

Equipment protected throughout by double 
insulation or reinforced insulation.

Application around and removal from 
UNINSULATED HAZARDOUS LIVE 
conductors is permitted.

 Direct current

 Alternating current

CAT III: 

      Applicable to test and measuring circuits connected to 
the distribution part of the building's low-voltage MAINS 
installation.Example:fixed equipment switchboards,circuit 
breakers,wiring,including cables,bus bars,junction boxes,
switches,sockets,utput terminals on devices for industrial 
use and other equipment.

Содержание MS2601

Страница 1: ...MS2601 Electrical Tester User s Manual CAT III 600 V 600V CAT III Hz A V Loz A Temp FUNC RAN Hz NCV MS2601 ELECTRICALTESTER 600V CAT III COM MAX 200A Temp A...

Страница 2: ...ode 7 Backlight and worklight 8 Auto Power Off 8 Measurement Preparation 8 AC Current 9 Switching Between Functions 7 AC DC Voltage 10 Resistance 11 Diodes 12 Continuity 11 Capacitance 12 Non Contact...

Страница 3: ...ument to Mastech no service will be provided without a return authorization The user is responsible for properly packing the unit and charges such as shipping freight and insurance charges The extent...

Страница 4: ...e circuit first before switching between functions 12 Disconnect power and discharge all capacitors before measuring resistance capacitance continuity or diodes 13 Do not measure capacitance before th...

Страница 5: ...een functions RAN button to switch to manual range button to hold the reading or to turn on backlight Hz button to switch between frequency and duty cycle NCV button to activate non contact voltage de...

Страница 6: ...t automatically turns off To turn off the backlight manually hold again When the meter is in current mode turning on the backlight will also activate the worklight making it easier to use the clamp in...

Страница 7: ...into INPUT jack 2 Turn the rotary switch to the V The default mode is DC voltage press FUNC to switch to AC voltage if necessary press FUNC to switch back to DC voltage 3 Connect the test leads across...

Страница 8: ...istance is less than 50 the meter s buzzer will sound Note If the resistance is higher than 60M or the leads are disconnected the display shows OL Capacitance TO AVOID ELECTRICAL SHOCK AND INJURY TURN...

Страница 9: ...lead into INPUT jack 2 Turn the rotary switch to the position Press FUNC to switch to AC voltage 3 Press Hz button to measure frequency 4 Press Hz again to measure duty if necessary 5 Connect the test...

Страница 10: ...ault mode is F press FUNC to switch to C if necessary press FUNC to switch back to F 3 Touch the tip of the thermocouple to the object to be tested 4 Read the measured temperature value on the display...

Страница 11: ...true reading will be shown 600mV 0 1mV 1000 A AC Voltage 0 8 reading 3 digits Range Resolution Accuracy 6V 0 001V 60V 0 01V 600V 0 1V Input impedance 10M Maximum input voltage 600V DC AC rms Frequency...

Страница 12: ...measured resistance is less than 50 0 1 Description Function Resolution Continuity Over voltage protection 250V DC AC rms Diodes Displays forward biased voltage drop 0 001V Description Function Resolu...

Страница 13: ...meter or personal injury To avoid electrical shock remove test leads from input jacks before cleaning To avoid false readings that could lead to possible electric shock replace the batteries as soon...

Страница 14: ...electric shock make sure the probes are disconnected from the measured circuit before removingthe rear cover Make sure the rear cover is tightly screwed before using the instrument Warning Out of the...

Отзывы: