Technical Specifications
Temperature: 23±5
℃.
Relative humidity: <75%
AC Current
• Maximum input current: 200A AC
• Frequency Range: 40 ~ 400Hz
±(3.0% 3 digits)
200A
0.1A
Range
Resolution Accuracy
DC Current
• Maximum input current: 1000µA DC
±(1.0% 4 digits)
600µA
0.1µA
1µA
Range
Resolution Accuracy
DC Voltage
±(0.7% 3 digits)
Range
Resolution Accuracy
6V
0.001V
60V
0.01V
600V
0.1V
• Input impedance: 10MΩ
• Maximum input voltage: 600V DC/AC rms
Note:
At small voltage ranges, unsteady readings will appear
before the test leads make contact with the circuit. This is
normal since the meter is highly sensitive. When the test
leads are connected to the circuit, the true reading will be
shown.
600mV
0.1mV
1000µA
AC Voltage
±(0.8% 3 digits)
Range
Resolution Accuracy
6V
0.001V
60V
0.01V
600V
0.1V
• Input impedance: 10MΩ
• Maximum input voltage: 600V DC /AC rms
• Frequency Range: 40 ~ 400Hz
Note:
At small voltage ranges, unsteady readings will appear
before the test leads make contact with the circuit. This is
normal since the meter is highly sensitive. When the test
leads are connected to the circuit, the true reading will be
shown.
LOZ
±(2.0% 3 digits)
Range
Resolution Accuracy
ACV
1-600V
DCV
1-600V
• Input impedance: 10M
• Maximum input voltage: 600V DC/AC rms
• ACV Frequency Range: 40 ~ 400Hz
Note:
At small voltage ranges, unsteady readings will appear
before the test leads make contact with the circuit.
This is normal since the meter is highly sensitive.
When the test leads are connected to the circuit,
the true reading will be shown.