27
7.2.2 Intermediate load 2
5. Keep the door ajar slightly.
6. Close the door approximately
after 10 mins
making sure that the kindling is well alight. Do not change
the air slide position at this stage.
7.
After 15~17 mins
, once the small logs are more than 50% burnt, open the door to add 2
nd
intermediate
load, i.e., 4 pieces of medium firelogs. Close the door and continue to lite the fire on the "HIGH" air
slide setting.
(5)
(6) – 10 mins
(7) – 15~17 mins
(8) – 40~45 mins
DO NOT LEAVE BURNER UNATTENDED DURING THIS INITIAL LIGHT-UP PERIOD
7.2.3 Main load and controlling output
8. Around 40~45 mins, when the intermediate load 2 is burnt more than 50%, open the door for loading
the main load.
9. Add 3 large size logs and close the main fuel loading door.
10. Once the large size logs are fully alight, the burner is ready to adjust the output by operating the air
slide.
11. Adjust the air slide to the medium of low position to control the output.
(9) – 40+mins
(10) – 50+ mins
(11) – 70+ mins
Always open the door in two stages :
1. Unlatch the door and keep it slightly ajar for 15~20 seconds
2. Then open the door fully.
Always switch the air slide knob gently and gradually.
This practice is essential to avoid puff of smoke coming into the room.
7.2.4 Refueling and Shut-down
12. Before opening the door for reloading, make sure that the air slide is on the
"HIGH"
setting. Reload
one or two logs at a time. After reloading, keep the air slide to the
"HIGH"
position till logs are fully
alight.
13. To shut down the burner, let the fire extinguish and leave the burner doors closed until it has cooled
down
Содержание RANGITATA ULEB
Страница 21: ...21 Fig 14 Contents of the Rangitata Zero Clearance Box Pack ...
Страница 34: ...34 ...