Masport PG33 Gas Inbuilt
19
Horizontal Flueing with Two (2) 90
o
Elbows
Option V
H + H1
A) 0.3m Min. 0.9m Max.
B) 0.6m Min. 1.2m Max.
C) 0.9m Min. 1.5m Max.
D) 1.2m Min. 1.8m Max.
E) 1.5m Min. 2.1m Max.
F) 1.8m Min. 2.4m Max.
Horizontal Flueing with Two (2) 90
o
Elbows
Horizontal Flueing with Three (3) 90
o
Elbows
Option H
V
H + H1 + H2
A) 0.3m Max. 0.3m Min. 0.9m Max.
B) 0.6m Max. 0.9m Min. 1.5m Max.
C) 0.9m Max. 1.5m Min. 1.8m Max.
D) 1.2m Max. 2.1m Min. 2.1m Max.
E) 1.5m Max. 2.7m Min. 2.4m Max.
F) 1.8m Max. 3.3m Min. 2.7m Max.
With these options, max.
total pipe length is 30
feet with min. of 11 feet
total vertical and max. 9
feet total horizontal.
Please note min.
1 foot between 90
o
elbows is required.
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
INSTALLATION
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
Option H
V
H + H1
A) 0.3m Max. 0.3m Min. 0.9m Max.
B) 0.6m Max. 0.9m Min. 1.5m Max.
C) 0.9m Max. 1.5m Min. 1.8m Max.
D) 1.2m Max. 1.8m Min. 2.1m Max.
E) 1.5m Max. 2.4m Min. 2.4m Max.
With these options, max. total
pipe length is 30 feet with min.
of 8 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.