background image

OPERATING INSTRUCTIONS

Содержание BOWDEN MINI

Страница 1: ...OPERATING INSTRUCTIONS...

Страница 2: ...MBM150 BOWDEN MINI Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA VERSION 1 0...

Страница 3: ...Fuel Quality 4 6 2 Flue Draught 4 7 Ash Removal 5 8 Flue Chimney Fire 5 9 Cleaning Paintwork and Glass 5 10 Cleaning the Flue 5 11 Troubleshooting Tips 6 11 1 Glass in Door Blackening 6 11 2 Trouble...

Страница 4: ...liance to emit smoke into the room 1 1 AIR CONTROLS The Masport Bowden range of wood heaters feature a single air control system It is designed to introduce oxygen into the base of the fire controllin...

Страница 5: ...6 Close the door Do not leave fire unattended while the door is open 5 RUNNING THE APPLIANCE 5 1 MAXIMUM HEAT OUTPUT After establishing the fire and loading it with larger pieces of wood leave it runn...

Страница 6: ...d up in the flue chimney Low heat output Short burn times and blue grey smoke from the flue chimney outlet Run appliance at high heat output for a short period each day to avoid large build up of tars...

Страница 7: ...E Check inside of flue prior to each season for any build up of creosote wood tar To do this 1 First remove the baffle refer to 2 Replacement of Baffle Plate under Maintenance Servicing section 2 Usin...

Страница 8: ...ly insulated or in a position that results in a downdraught then there will be insufficient flue draught Contact the installer should this happen 11 2 TROUBLE STARTING THE FIRE If all ash has been rem...

Страница 9: ...so that they do not go straight up the flue Over time the baffle may begin to deteriorate a little due to the excessive heat This will not affect the way the fire burns Eventually the baffle may wear...

Страница 10: ...may mean that there is an air leak around the door In this situation the door seal does not necessarily need replacing adjustment of the latch can tighten the seal To adjust the door latch 1 Using th...

Страница 11: ...his task must be performed with the door removed from the appliance and laid horizontally on a work bench To replace the door glass 1 Place the door glass side down on a work bench Remove the 8x M6 nu...

Страница 12: ...convection It applies from the date of purchase from or through an authorized Masport Fire Distributor in relation to each product or component for the period below TYPE OF PART WARRANTY IN YEARS PART...

Страница 13: ...n normal wear and tear misuse neglect accidental damage or failure to follow operating instructions in the Owner s Manual including fuel selection product operation and maintenance instructions repair...

Страница 14: ...ustralia Pty Ltd 8 Lakeview Drive Scoresby Victoria 3179 Australia T 1300 556 816 F 1800 058 900 General and Sales Enquiries flame glendimplex com au Technical Service service glendimplex com au www g...

Отзывы: