Masport BOWDEN MINI Скачать руководство пользователя страница 4

2

USER INSTRUCTIONS

1. 

INTRODUCTION

Before use of this appliance please read these 
instructions fully.

WARNING: ANY MODIFICATION OF THE APPLIANCE 
THAT HAS NOT BEEN APPROVED IN WRITING BY THE 
TESTING AUTHORITY IS CONSIDERED AS BREACHING 
AS/NZS 4013.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR 
AEROSOLS TO START OR REKINDLE THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR 
AEROSOLS IN THE VICINITY OF THIS APPLIANCE 
WHEN IT IS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN HEATER 
INSTALLATION CLEARANCES.

WARNING: WHEN OPERATING THIS APPLIANCE AS AN 
OPEN FIRE USE A FIRE SCREEN.

WARNING: OPEN AIR CONTROL BEFORE OPENING 
DOOR.

WARNING: DO NOT BURN WOOD THAT IS PAINTED; 
OR IS COATED WITH PLASTIC; OR HAS BEEN TREATED 
WITH ANY CHEMICAL.

CAUTION: THIS APPLIANCE SHOULD NOT BE 
OPERATED WITH CRACKED GLASS.

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED 
AND OPERATED AT ALL TIMES IN ACCORDANCE WITH 
THESE INSTRUCTIONS.

The appliance or flue system should not be modified in 
any way without the written approval of the manufacturer.

Extraction fans or rangehoods must not be placed in the 
same room or space, as this can cause appliance to emit 
smoke into the room.

1.1. 

AIR CONTROLS

The Masport Bowden range of wood heaters feature 
a single air control system. It is designed to introduce 
oxygen into the base of the fire, controlling the rate of 
combustion of the wood. In addition, oxygen is drawn into 
the upper firebox where combustion of the gases occurs.  

The air control is operated by sliding the black metal tab 
located on the top right side of the heater. Pulled all the 
way out offers maximum burn rate, while pushed all the 
way in offers minimum burn rate. See below:

The air slide tab may become hot when fire has been 
burning for some time.

Secondary air holes in the rear of the firebox provide 
additional oxygen for a more complete combustion of the 
gases released from the burning wood.

1.2.  DOOR HANDLE

Warning: the door handle may get hot if appliance has 
been left in high burn setting for an extended period of 
time. Please exercise caution when operating.

2. 

USING THE APPLIANCE FOR THE 
FIRST TIME

The first few times the appliance is lit, it will give off some 
odorous fumes. This is caused by the paint curing.

Do not touch the paint work while it is curing otherwise it 
can leave a permanent mark on the appliance.

Once the paint has cured it will not re-occur.

Keep the room well ventilated until these fumes have 
cleared.

Содержание BOWDEN MINI

Страница 1: ...OPERATING INSTRUCTIONS...

Страница 2: ...MBM150 BOWDEN MINI Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA VERSION 1 0...

Страница 3: ...Fuel Quality 4 6 2 Flue Draught 4 7 Ash Removal 5 8 Flue Chimney Fire 5 9 Cleaning Paintwork and Glass 5 10 Cleaning the Flue 5 11 Troubleshooting Tips 6 11 1 Glass in Door Blackening 6 11 2 Trouble...

Страница 4: ...liance to emit smoke into the room 1 1 AIR CONTROLS The Masport Bowden range of wood heaters feature a single air control system It is designed to introduce oxygen into the base of the fire controllin...

Страница 5: ...6 Close the door Do not leave fire unattended while the door is open 5 RUNNING THE APPLIANCE 5 1 MAXIMUM HEAT OUTPUT After establishing the fire and loading it with larger pieces of wood leave it runn...

Страница 6: ...d up in the flue chimney Low heat output Short burn times and blue grey smoke from the flue chimney outlet Run appliance at high heat output for a short period each day to avoid large build up of tars...

Страница 7: ...E Check inside of flue prior to each season for any build up of creosote wood tar To do this 1 First remove the baffle refer to 2 Replacement of Baffle Plate under Maintenance Servicing section 2 Usin...

Страница 8: ...ly insulated or in a position that results in a downdraught then there will be insufficient flue draught Contact the installer should this happen 11 2 TROUBLE STARTING THE FIRE If all ash has been rem...

Страница 9: ...so that they do not go straight up the flue Over time the baffle may begin to deteriorate a little due to the excessive heat This will not affect the way the fire burns Eventually the baffle may wear...

Страница 10: ...may mean that there is an air leak around the door In this situation the door seal does not necessarily need replacing adjustment of the latch can tighten the seal To adjust the door latch 1 Using th...

Страница 11: ...his task must be performed with the door removed from the appliance and laid horizontally on a work bench To replace the door glass 1 Place the door glass side down on a work bench Remove the 8x M6 nu...

Страница 12: ...convection It applies from the date of purchase from or through an authorized Masport Fire Distributor in relation to each product or component for the period below TYPE OF PART WARRANTY IN YEARS PART...

Страница 13: ...n normal wear and tear misuse neglect accidental damage or failure to follow operating instructions in the Owner s Manual including fuel selection product operation and maintenance instructions repair...

Страница 14: ...ustralia Pty Ltd 8 Lakeview Drive Scoresby Victoria 3179 Australia T 1300 556 816 F 1800 058 900 General and Sales Enquiries flame glendimplex com au Technical Service service glendimplex com au www g...

Отзывы: