l
Remove the blocking tool.
l
Open the 4 screws and remove the fixation plate.
Mind the lock washers! These need to be replaced every time the screws are
opened.
Removing the rotor and gate
l
Screw in the 4 shaft extensions
•
The fixation plate can be used as a stopper
l
Pull the rotor, together with the gate, out of the housing, as shown.
Note: The gate can be changed in this position
•
Open the screws and remove the fixation plate
•
Use the fixture to lift the rotor