background image

 

 

 

 

Doc.Ref.No.:m92A/om/101-1 
Issue No.:02 

9000L 

 

 
 

INDEX 

A

PPLICATION 

E

XAMPLE

……………………………………………………………………………………

 

S

PECIFICATION

………………………………………………………………………………………………… 

S

AFETY AND WARNING

……………………………………………………………………………………... 

3

 

C

ONNECTION

…………………………………………………………………………………………………… 

3 

I

NSTALLATION

………………………………………………………………………………………………….. 

3 

O

RDERING CODE

……………………………………………………………………………………………… 

4 

T

ROUBLE SHOOTING

………………………………………………………………………………………… 

4

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Содержание 9000L Series

Страница 1: ...Doc Ref No m92A om 101 1 Issue No 02 9000L INDEX APPLICATION EXAMPLE 1 SPECIFICATION 2 SAFETY AND WARNING 3 CONNECTION 3 INSTALLATION 3 ORDERING CODE 4 TROUBLE SHOOTING 4 ...

Страница 2: ...tile environments with full 3 port isolation between input output and power supply 9000L is flexible for DIN rail mounting and easily installable Its compact design consumes less space and hence reduces cost of overall installation FEATURES Slimmest in its class 35 mm Single output and Dual output Extended Universal Power Supply Range 20V to 265V DC or AC Active Output LED indication Rugged accura...

Страница 3: ...er Consumption Less than 5VA CMRR 100dB NMRR 70dB Isolation Isolation Power to Input Output Input to Output Output to Output 1 5KV AC for 1 minute Environmental Operating temperature 0 to 55ºC Temp Co efficient 100 PPM Relative humidity 30 to 95 RH Non Condensing Protection Conformal Coating on PCB Physical Mounting Type DIN RAIL 35 mm Mounting Dimensions 35 1 W x75 H x107 25 D mm For SOP DOP Weig...

Страница 4: ...ce output current or have separate fuse protection Sufficient convection is ensured After installation the terminal area must be covered to provide sufficient protection against unauthorized Access to live parts This is ensured by installing the device in the control Cabinet or distributor box CONNECTION Connection details Block Diagram and connection details of SOP Note In case of DC supply conne...

Страница 5: ...ect to input signal before attempting any re calibration Unstable Reading Check for loose connections First verify that all conventional instrumentation norms have been followed for wiring Make noise away from signal isolator Fluctuation in Reading The reason can be reverse input connections Ordering Code Model No of O P 9000L S X 1 One 2 Two Ordering Code Model Input Type O P type 1 O P type 2 90...

Отзывы: