8 TRANSPORT, STORAGE, LIFTING AND, HANDLING AND PACKAGING

8.1 T

RANSPORT

 

AND

 

STORAGE

Packaging: Supplied directly by Mase Generators.
The total weight of the packed generator is given in Paragraph 2.4 “Table of technical characteristics”.
It is strictly prohibited to pollute the environment with the packaging

Transport: During transport  the generator (with or without packaging) must be protected against atmospheric
agents, it must not be turned upside down and must be protected against knocks. The generator must be transported
without fuel to prevent leaks during travel.

Storage: The generator must be stored in horizontal position and away from atmospheric agents and humidity.

8.2 L

IFTING

 

AND

 

HANDLING

All the lifting operations must be carried out by personnel
specialised in this type of work, such as truck drivers,
crane drivers, slingers.

 The operator is considered

responsible for using the correct machine slinging and
lifting technique.

8.2.1 L

IFTING

 

AND

 

HANDLING

 

WITH

 

CRANE

The machine must be lifted and handled with the systems
indicated in the picture. Check that the hoisting cables or
chains are homologated or of sufficient capacity, and also
check the minimum cable length. Calculate the cable
capacity considering that for each of the two sling sections
a weight about double that shown on the identification plate
of the machine has to be supported (this is to compensate
for the cable angle). Always use the eyebolts provided by
the manufacturer and always marked with a pictogram.

ALWAYS TAKE THESE PRECAUTIONS WHEN
LIFTING THE GENERATOR:

Do not swing suspended loads.
Never leave the load unattended.
Lower the generator to the ground very slowly.
Always maintain the safety distance.

The gravity centre of the generator corresponds to
about the centre of its geometrical volume.

8.2.2 L

IFTING

 

AND

 

HANDLING

 

WITH

 

FORKLIFT

 

TRUCK

Use a forklift truck with wide forks and of adequate
capacity and lift in a barycentric position (which
corresponds to about the centre of its geometrical
volume).

The trailed version cannot be lifted with a forklift.

The hoisting structure has been designed to hold the
generator suspended for the time strictly necessary
to move it.

DO NOT PARK THE SUSPENDED
GENERATOR !

Содержание MPL 206 A

Страница 1: ...od 42934 GRUPPO ELETTROGENO MANUALE DI USO E MANUTENZIONE I Tipo modello N matricola Codice GENSET USE AND MAINTENANCE MANUAL GB GROUPE LECTROG NE MANUAL DE USO Y MANTENIMIENTO E ELEKTROAGGREGATEBRAUC...

Страница 2: ...entilation 18 3 5 Fuel system 18 3 6 Electrical connection 18 3 6 1 Power cables sizes 18 3 6 2 Powercableconnection 19 3 6 3 Groundconnection 19 3 7 Outdoorinstallation 20 3 8 Insideinstallation 21 4...

Страница 3: ...or and for the modern conception the strong sizing the materials employees the continuous updatings constitutes an effective answer to the operators demands of the sector This Manual instructions will...

Страница 4: ...tically by differential effect Skilled person Apersonwithtechnicalknow howorsufficientexperiencetoallowhimtoavoidthedangersinherentinelectricity MASE specialised personnel A person able to evaluate th...

Страница 5: ...on Indicatesthatparticularattentionmustbepaidinordertopreventseriousriskswhichcould lead to death or possible harm to the health of personnel Aconditionwhichmayoccurduringthelifetimeofaproduct systemo...

Страница 6: ...ied out by technicians authorised by the local dealer or the manufacturer Only mase technicians or personnel trained by mase have the necessary knowledge of the generator and the special equipment as...

Страница 7: ...MATICO A DISTANZA STARTING AUTOMATIC REMOTE FERNSTARTVORRICHTUNG AUTOMATICA A DISTANCIA MACHINE A DEMARRAGE AUTOMATIQUE A DISTANCE I GB D E F Cod 42347 Cod 42118 Cod 42467 Cod 41776 E E L L STOP E S D...

Страница 8: ...theUseandMaintenanceManualbeforestartingthegenerator TheMasegeneratorhasbeendesignedsoastoguaranteesafeandreliableoperation provided that the instructions are followed Otherwise personal injury or dam...

Страница 9: ...tanglement and cutting Presence of rotating parts pulleys belts and fan Danger of burns Hot surfaces Danger of burns Possibility of pressurised hot water expulsion Obligation Symbols Meaning Obligatio...

Страница 10: ...ersons or things deriving from inobservance of the safetyregulations Carefully examine the safety warning plates on the generator and respect the relevant instructions 1 5 1 DANGER OF ENTANGLEMENT Do...

Страница 11: ...ing that fuel does not overflow from the engine tank respecting the maximum level In the event of fuel spillage from the tank thoroughly dry and clean the parts involved Check that there are no fuel l...

Страница 12: ...withArticles313and318ofPresidentialDecreeNo 54727 04 55 aswellasChap 11SectionIV oftheCEI64 8regulation Immediatelychangewetoveralls Insulate all the connectors and detached wires Donotleavethepowerte...

Страница 13: ...yareprovidedofaEC DeclarationofConformity 98 37 ECandsubsequentamendments Essential machine requirements for safety and health protection Machine directive Directive 2006 95 EC 73 23 EC and subsequent...

Страница 14: ...of malfunctioning Thegeneratorisparticularlyquietthankstoaninternally insulatedsoundproofcasingandanadvancedsoundproof system for combustion smoke exhaust Thealternatorsusedarethesynchronousself ener...

Страница 15: ...otection module see par 5 6 Lowvoltagetermalprotection 7 Fuellevel 8 Generalmagnetothermalswitch 2 3 1 DIFFERENTIAL MEGNETOTHERMAL PANEL VERSION OPTIONAL 8 Differentialmagnetothermalswitch 2 3 2 SOCKE...

Страница 16: ...OUS POWER PRP 2 180 205 kVA POWER FACTOR Cos THREEPHASE VOLTAGE V Hz GRADE OF PROTECTION MAX TEMP OF USE C MIN TEMP OF USE C MAX ALTITUDE OF USE m COOLING AIR FLOW m3 min L mm DIMENSIONS W mm H mm MAS...

Страница 17: ...l engines inasmuch the deratingofthepowergeneratoringeneralcoincideswith the derating of the Diesel engine Particular deratings may be determined on the basis of the effective conditions of use Forinf...

Страница 18: ...fixed protection to preventtheingressofrainwater Sectionsofpipespassingthroughwallsmustbeinsulated to prevent the transmission of heat to the walls themselves 3 3 2 EXHAUST PIPE DESIGN Thebackpressure...

Страница 19: ...espective terminal indicated by the icon ref 6 Thesizingofthegroundwirestothegroundsystemandthe relative contact resistance must comply with current laws andstandards Do not tamper with the active pro...

Страница 20: ...e placed on a flat surface For permanent or long term installations it is advisable to prepare a concrete foundation The area where the power set is installed must be suitably fenced off in order to p...

Страница 21: ...fficient recirculation of air Installation of exhaust piping to the exterior of limited length and the fewest possible number of curves is compulsory Thesystemmaybearrangedwithsufficientpassage space...

Страница 22: ...oxic and inflammable and must therefore bekeptinspecialairtightcontainersandstoredin inaccessibleplaces Refuelling must be carried out with the generator off and the key selector in position 0 STOP Do...

Страница 23: ...cap 2 2 rif U Havingremovedthecausesthatdeterminedtheneedfor anemergencystop releasetheemergencystopbutton in order to return to the operating conditions 5PROTECTIONSANDWARNINGSIGNALS Thegeneratorsar...

Страница 24: ...e engine is switched on 2 Switchedoffduringnormalengineoperation 3 Switched on with low level fuel Low oil pressure alarm LED ref 4 1 Indicate the input state before the engine is switched on 2 Switch...

Страница 25: ...indicated in ref 2 For detailed information in this connection consult the engineuseandmaintenancemanualwhichaccompanies the machine To change the oil in the oil sump first remove the dipstick ref 3 t...

Страница 26: ...efficient filter may cause loss of engine power and excessive smoke at the exhaust Toreplacetheairfilter carryoutthefollowingoperations Removethecover ref 1 fromthefilterholderbyacting on the crooks r...

Страница 27: ...10 hours CHECKS REGULARITY Check oil level sump daily Theroutinemaintenanceoperations mustbecarriedoutby qualifiedpersonnelwhohavetheappropiateequipmentand protections Adjust valve clearance 1500 hour...

Страница 28: ...nsult Service Centre Check the setting of the injectors Consult Service Centre There is high smoke emission from the exhaust Check the air filter Clean its elements or if necessary replace them Check...

Страница 29: ...lifted and handled with the systems indicated in the picture Check that the hoisting cables or chains are homologated or of sufficient capacity and also check the minimum cable length Calculate the ca...

Страница 30: ...ectitagainstdustand impurities Thepackagingisclearlyidentifiedwithanadhesivelabel indicating the type of model code and serial n of the group ref 3 After aperture all packaging materials must be colle...

Страница 31: ...manual The installation is carried out according to mase instructions The service procedures are carried out exclusively by mase specialised technical personnel The electrical system and the loads to...

Страница 32: ...15 EMERGENCY STOP BUTTON 16 ELECTRONIC VOLTAGE REGULATOR 17 ROTOR 18 STATOR 19 THERMAL SWITCH 20 15 POLES CONNECTOR 21 BUTTON 22 BUTTON 23 THERMAL SWITCH 24 ENGINE THERMOSTAT 25 AMPEROMETRIC TRANSFORM...

Отзывы: