DHW Set Point Change Modes
The FT Series Wall Mounted, Combination Boiler
Page 55
5.4 Status Display Mode
AUTODESK � � � � � � � � � �
AUTODESK �
�
�
�
�
�
�
�
�
�
AUTODESK ��
� �
��
� �
��
AUTODESK �
�
�
�
�
�
�
�
�
�
SECTION 5. Control Display and Operation
Digital Display
Status Display Parameter
Description
O:ot
Outdoor temperature
Current Outdoor temperature
A: Li or A: GA
Flow unit
Current fl ow value(Li: L/m, GA: GPM)
b: It
CH Return Water Temperature
Current Return Water Sensor Temperature
C: Fr
Fan rpm
Current fan rpm value
d: Lc
Lock mode
Lock mode ON/OFF
E: oP
OP temperature
Current OP temperature
F: dH
DHW temperature
Current DHW temperature
H: Eh
Exhaust temperature
Current Exhaust temperature
I : St
N/A
Not Used (Default is 0)
J: oH
Overheat temperature
Current Overheat temperature
L: rt
1: PH
Burner Opera-
tion Time
Supply power time
Supply power time x 100 hour
2: rh
Burner operation
time
Burner operation time x 1 hour
3: rH
Burner operation
time
Burner operation time x 1,000 hour
4: It
Ignition cycles
Ignition cycles x 10 times
5: IH
Ignition cycles
Ignition cycles x 10,000 times
P: Ou
Displays output condition for internal
primary pump and three way valve.
- Off
- On
1st Icon
2nd Icon
3rd Icon
Not Used
Internal CH
Pump
3 Way Valve
To change any of the above listed Status Parameters,
Press and Hold Button B
to get into the Status Display Mode.
Rotate Dial E until you fi nd the Parameter that you wish to change. Tap Dial E to enter that Parameter.
Adjust to the setting that you require and then press (tap) Dial E to save and to Exit.