background image

H2372900D

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Customer Service and Product Support:  

800.900.9276 • Fax 800.559.1583

  

20

 Industrial Way, Rochester, NH, USA  03867

   1706   Document 1319D

Содержание FTCW series

Страница 1: ...h could cause serious injury property damage or death Improper installation and or operation will void the warranty AVERTISSEMENT Assurez vous de bien suivres les instructions donn es dans cette notic...

Страница 2: ...lock a free flow of air to the boiler to ensure proper ventilation If desired clean the jacket surfaces with a damp cloth and mild detergent Do not use flammable cleaning materials If sidewall vented...

Страница 3: ...ction 11 CH Return Connection 12 CH Pressure Gauge 13 DHW Outlet Connection 14 Gas Inlet Connection 15 DHW Inlet Connection filter and flow restrictor Name of Component 16 Condensate Connection 17 Con...

Страница 4: ...ons Temperature Specifications Operating ambient Temperature Range 10 to 60 C Operating Relative Humidity up to 90 at 40 C Shipping Storage Temperature Range of 20 to 80 C Buttons Functionality PRESS...

Страница 5: ...Numeric Display Number and character display to display all parameters DHW mode Combination boiler Set Point can be adjusted Outside temp or 0 10 V mode Operating by outside temperature or 0 10V Numer...

Страница 6: ...ll go through a Start Up checklist and briefly show a sequence of diagnostic codes before entering into the Operating Mode It will then display the following information Indicate Example Current Opera...

Страница 7: ...t temperature I St N A Not Used Default is 0 J oH Overheat temperature Current Overheat temperature L rt 1 PH Burner Opera tion Time Supply power time Supply power time x 100 hour 2 rh Burner operatio...

Страница 8: ...rn dial E clockwise to increase and counterclockwise to decrease until desired temperature is reached Press dial E to save setpoint changes and to Exit Indicate Example Current DHW set point temperatu...

Страница 9: ...rol Display and Operation 5 6 CH Set Point Change Mode Changing between Celsius and Fahrenheit When the button D is pressed for more than 5 seconds temperature unit will toggle between C and F To chan...

Страница 10: ...Page 10 Notes...

Страница 11: ...User s Manual The FT Series Wall Mounted Combination Boiler Page 11 Notes...

Страница 12: ...cations subject to change without notice in accordance with our policy of continuous product improvement Customer Service and Product Support 800 900 9276 Fax 800 559 1583 20 Industrial Way Rochester...

Отзывы: