Marathon SL
47/48
Settings
NEGATIVE AIR
Use the MARZOCCHI pump with pressure
gauge to inflate the fork legs.
Using inadequate tools may lead to a
wrong inflation and result in a
malfunctioning or damage to the fork.
To reduce the leg’s pressure, simply push
the valve pin down with a pointed tool such
as a small pin extractor.
Drawing in compressed air through the
negative air valve (
B
) changes the damping
of the forces resulting from the REBOUND
of the fork legs.
Install the pump adapter provided with the
fork.
· Loosen and remove the protection cap (
A
)
on the left leg.
Screw the pump adapter (
C
) down on the
central valve (
A
)
· Inflate till reaching the pressure you wish
(see table).
Refit and tighten the protection cap (
B
).
The pressure values in the table are given
as a mere example and can be changed to
meet the biker’s riding style and the track
condition.