Model Specifications Appendix
8.1 Approved Operating Conditions
•
Use only inside dry buildings
•
Ambient temperature 0-50°C (32-122°F)
•
Operational altitude: max. 2000 m (1.242 mi) above sea level
•
Max 80% relative humidity, non condensing
8.2 Model Data-Table Footnotes
Note that throughout the specs, Unom (nominal voltage), Inom (nominal current), and Pnom (nominal power) all refer to
the product’s rated values. Therefore, a unit rated for 360 V, 30 A, and 3 kW has a Unom of 360, an Inom of 3s0, and a
Pnom of 3 or 3000 depending on whether the specification calls out kW or W.
For the model-specific data tables on the following pages, these are the referenced footnotes.
1.
Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the
true (actual) value.
•
Example: an 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the
actual value is allowed to differ up to 80 mV, which means it might be between 4.92 V and 5.08 V.
2. The display error adds to the error of the related actual value on the DC output
3. RMS value: LF 0–300 kHz, PP value: HF 0–20MHz
4. Typical value at 100% output voltage and 100% power
5.
Allowed float (potential shift) on the DC output