US- 14 -
7. After the engine starts, move the throttle setting lever
to the idle position, then move the choke lever to the
open ( ) position.
If the engine stops running before you move the choke
lever to the open ( ) position:
A. Go ahead and open the choke.
B. Make sure the throttle setting lever is set to the idle
position.
C. Pull the starter grip until the engine starts.
Hot Restart
To start the engine that is already warmed up (hot restart),
or if the ambient temperature exceeds 68°F (20°C):
1.
Pump the primer bulb at the bottom of the carburetor
until fuel can be seen flowing through the fuel return
line to the fuel tank.
2.
Move the choke lever to the open ( ) position and
move the stop switch to the “ON” position.
3.
More the throttle setting lever to the idle position and
pull the starter grip.
4.
If the engine fails to start after three to four pulls,
follow the instruction in the Cold Starting Procedure
section (page US 13).
If the engine fails to start after you follow the above
procedures, contact an authorized MARUYAMA
dealer.
Note: 1. Don't pull the starter cord out completely.
2. Do not release the starter cord from the
fully extended position
To Stop The Engine:
1.
Move the throttle setting lever to the idle position.
Release the throttle trigger.
2.
Slide the stop switch to the “STOP” position.
Handheld Blower
Operation
1.
Allow the engine to warm up for a few minutes.
2.
Control engine speed by the throttle trigger, or set the
engine speed by the throttle setting lever.
*To adjust the throttle setting lever.
Press the throttle trigger, then adjust the throttle
setting lever as you wish operation.
3.
Operate lower speed to blow leaves or debris ground.
4.
If the blow is not enough to blow, open the throttle
gradually.
Note: Operate Handheld Blower at the lowest throttle