3.4 Class II Test
Always refer to and perform 3.1 before proceeding
The following are performed for a Class II appliance test:
Fuse check
- checks Live-Neutral continuity through
appliance.
Insulation measurement
- measures resistance
between live and exposed metalwork and between
neutral and exposed metalwork.
Test Connections
u
Refer to the Class II connection diagram below.
u
Plug the appliance mains plug into the HPAT500 front
panel mains socket (1).
u
Connect the test probe to the HPAT500 4mm test
probe socket (2) and connect the other end to any
exposed metal work on the appliance.
u
Switch ON the test appliance.
Class II Test
Connection
Automatic Test Sequence
u
Press
CLASS II
to select the Class II appliance test
and display the test screen.
14