50
VDO Face 5™ user manual
P3 Signal Protocol
Signal type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gigabit Ethernet
Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Proprietary Martin® P3
Hot pluggable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes, electrically insulated at all connections
Cable type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ethernet, Cat 5e or better
Cable length. . . . . . . . . . . . Up to 100 m (328 ft.) between any 2 devices, extendable with Ethernet switch
Max. number of devices per chain . . . . . . . . . . 50 (split and multiple chains possible with Ethernet switch)
Construction
Panel frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Die-cast aluminum
LED modules per panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 x quick-install, hot-swappable LED blocks
Color . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Matt black
Protection rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP65, NEMA 4
RoHS compliant
Installation
Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Any
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indoor or non-permanent outdoor installation
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . .Vertical columns via headers, creative layouts via panel clamps
Max. suspended from VDO Face headers. . . . . . 10 panels (safety factor 10) or 16 panels (safety factor 6)
Max. suspended from panel clamp (any orientation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 panel
Max. wind pressure suspended from VDO Face Headers. . . . . . . . . . Force 8 Beaufort, 20 m/s or 45 mph
Max. stacked on VDO Face Footer system . . . . . . . . . . . Up to 8 panels depending on installation method
Max. wind pressure standing on VDO Face Footers . . . . . . . . . . . . . . . . Force 2 Beaufort, 3 m/s or 7 mph
Panel interlocking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick-lock mechanism
Connections
Power in, power thru . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Neutrik PowerCON TRUE1
Data in, data thru . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Neutrik EtherCON Cat 6
Electrical
AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100-240 V nominal, 50/60 Hz
Power supply unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Integrated, auto-sensing multi-voltage
Inrush current (half-cycle RMS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7.9 A
VDO Face 5 HB
Peak power consumption (approx., at full intensity, full white) . . . . . . . . . . 191 W per panel, 679 W per m
2
Typical power consumption (with typical video content) . . . . . . . . . . . . . . . 64 W per panel, 226 W per m
2
VDO Face 5 HC
Peak power consumption (approx., at full intensity, full white) . . . . . . . . . . 260 W per panel, 924 W per m
2
Typical power consumption (with typical video content) . . . . . . . . . . . . . . . 87 W per panel, 309 W per m
2
Thermal
Cooling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Convection
Maximum ambient temperature (T
a
max.), full intensity, full white . . . . . . . . . . . . . . . . . . . . . 45° C (113° F)
Minimum ambient temperature (T
a
min.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20° C (-4° F)
VDO Face 5 HB
Typical total heat dissipation (calculated, per panel, with typical video content) . . . . . . . . . . . . 220 BTU/hr.
VDO Face 5 HC
Typical total heat dissipation (calculated, per panel, with typical video content) . . . . . . . . . . . . 300 BTU/hr.
Approvals
EU safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EN 60950-1, EN 62311, EN 62471
EU EMC . . . . . . . . . . . . . . . . . . . EN 55024, EN 55032, EN 61000-3-2, EN 61000-3-3
US safety (pending) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ANSI/UL 60950-1
US EMC . . . . . . . . . . . . . . . . . . . . . . . . FCC Title 15, Subpart B, Class A, ANSI C63.4
Canadian safety (pending) . . . . . . . . . . . . . . . . . . . . . . . . . CSA C22.2 No. 60950-1-03
Canadian EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ICES-003 Class A
Australia / NZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .RCM
Содержание VDO Face 5
Страница 1: ...VDO Face 5 Video Panel User Manual ...
Страница 4: ...4 VDO Face 5 user manual All dimensions are in millimeters VDO Face 5 Panel Clamp 50 0 ...
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ...www martin com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...