background image

RUSH SM 650

TM

 User Manual 

12

Remote control 

The SM 650 smoke machine comes with 2 remote control options: a wired remote 
control and a 4-channel wireless remote control. There are two identical sockets 
on the rear panel so that both remote controls may be connected and used at the 
same time.  

Wired remote control 

The wired remote control has a 4.5 m (15 ft.) cable that plugs into either remote 
control socket on the rear panel. The status LED on the remote control is off while 
the machine is heating and lights green when the smoke machine is ready for 
use.  

4-channel wireless remote control and receiver  

The 4-channel wireless remote control transmitter (shown below to left) has a 
range of 30 meters (100 feet). It provides individual control of up to 4 smoke 
machines and simultaneous control of an unlimited number of machines in up to 4 
groups.  

 

The remote control receiver (shown above to right) connects to a remote control 
socket on the rear panel. It has green (ready) and red (heating) LEDs to show the 
machine’s status.  

The DIP switch on the side of the receiver sets the remote control button that 
triggers the machine. Flip the switch that corresponds to the desired transmitter 
button to the ON position. Flip all other switches to OFF. The smoke machine 
responds to all buttons for which the DIP switch is in the ON position.  

Содержание Rush SM 650

Страница 1: ...SM 650 User Manual ...

Страница 2: ...nability to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional or its affiliates or subsidiaries Martin Professional Olo...

Страница 3: ... machine on a truss 10 Securing with a safety cable 11 AC power 11 Remote control 12 Wired remote control 12 4 channel wireless remote control and receiver 12 Operation 13 Filling the tank 13 Making smoke 13 Maintenance 14 Cleaning 14 Replacing the primary fuse 14 Replacing the wireless remote control battery 15 Service and repairs 15 Troubleshooting 16 Specifications 17 ...

Страница 4: ...s of severe injury or death due to fire and burn hazards electric shock falls and respiratory problems The smoke produced by the machine is hot enough to cause burns or eye injury if the safety precautions below are not followed Install operate and service RUSH by Martin products only as directed in their user manuals or you may create a safety hazard or cause damage that is not covered by product...

Страница 5: ...al power switches used to supply the smoke machine with power must be located near the smoke machine and easily accessible so that the smoke machine can easily be disconnected from power Replace defective fuses with ones of the specified type and rating only Disconnect the smoke machine from power immediately if the power plug or any seal cover cable or other component is damaged defective deforme...

Страница 6: ...ine Keep combustible materials at least 1 m 40 in away from the machine Do not attempt to bypass thermostatic switches or fuses Replace fuses only with ones of the type and rating specified in this manual for the machine Protection from injury Ensure that any supporting structure and or hardware used can hold at least 10 times the weight of all the devices they support If suspending from a rigging...

Страница 7: ...e water and obtain medical advice Block access below the work area and work from a stable platform whenever installing servicing filling or moving the smoke machine In the event of an operating problem stop using the smoke machine immediately and disconnect it from power Do not attempt to use a smoke machine that is obviously damaged Do not modify the smoke machine in any way Refer any service ope...

Страница 8: ...less remote control transmitter and receiver a 1 5 m 5 ft power cable local power plug not included on some models and an adjustable mounting bracket Before using the product 1 Read Safety information on page 4 before installing operating or servicing the smoke machine 2 Unpack and ensure that there is no transportation damage before using the smoke machine Do not attempt to operate a damaged smok...

Страница 9: ... Smoke machine overview 1 mounting bracket 6 power switch 2 clamp attachment point 7 remote control socket 3 fluid tank 8 remote control socket 4 secondary attachment point 9 AC power socket 5 smoke output nozzle 10 No fluid light ...

Страница 10: ...d to a truss or similar rigging structure and tilted up to 45 degrees from horizontal When installing the smoke machine with the mounting bracket hanging vertically down you can use an open type clamp such as a G clamp If installing with the mounting bracket in any other orientation you must use a half coupler clamp see illustration on right that completely encircles the truss chord To clamp the s...

Страница 11: ...power switches used to supply the smoke machine with power must be located near the smoke machine and easily accessible so that the smoke machine can easily be disconnected from power The smoke machine can be hard wired to a building electrical installation if you want to install it permanently or a power plug not supplied that is suitable for the local power outlets can be installed on the power ...

Страница 12: ...annel wireless remote control and receiver The 4 channel wireless remote control transmitter shown below to left has a range of 30 meters 100 feet It provides individual control of up to 4 smoke machines and simultaneous control of an unlimited number of machines in up to 4 groups The remote control receiver shown above to right connects to a remote control socket on the rear panel It has green re...

Страница 13: ... Replace the filler cap and verify that the feed hose touches the bottom of the tank 5 Wipe up any spills or drips Making smoke 1 Fill the fluid tank as described above 2 Connect a remote control or wireless remote control receiver as described on the previous page 3 Connect the smoke machine to AC power and switch it on Allow the machine to heat up for several minutes The machine is ready to use ...

Страница 14: ... machine Damage caused by inadequate cleaning or maintenance is not covered by the product warranty Inspect smoke machines within their first 100 hours of operation to see whether cleaning is necessary Check again at frequent intervals This procedure will allow you to assess cleaning requirements in your particular situation If in doubt consult your RUSH by Martin dealer about a suitable maintenan...

Страница 15: ...emove the old battery 3 Insert a fresh battery with the negative terminal towards the spring 4 Align the covers and replace the screw to close Service and repairs Do not try to repair the smoke machine by yourself as this may result in damage malfunction and it may potentially void your product warranty The equipment must only be serviced or repaired by an authorized RUSH by Martin service technic...

Страница 16: ...form output fluid drips or spits from nozzle or loud noise when firing machine Incompatible smoke fluid Discard fluid and replace with genuine Rush ELX Smoke Fluid No smoke output Machine not ready Allow machine several minutes to heat up Fluid level low Add fluid see page 13 Selected remote control button does not match receiver DIP switch setting Change DIP switch setting see page 12 or press a ...

Страница 17: ... kg 9 lbs Dimensions 263 x 283 x 224 mm 10 3 x 11 1 x 8 8 in Performance Max smoke output approx 160 m3 minute Max operating time at full output approx 12 seconds Warm up time approx 4 minutes Control Control options dedicated wired 4 button wireless remote control ...

Страница 18: ...um clearance around vents 0 5 m 19 7 in Connections AC power in IEC Wired remote control 5 pin DIN Wireless remote control receiver 5 pin DIN Electrical AC power EU model 220 240 V nominal 50 Hz AC power US model 100 120 V nominal 60 Hz Main fuse EU model 5 AT slow blow Main fuse US model 8 AT slow blow Typical power and current 100 V 60 Hz 717 W 7 17 A 120 V 60 Hz 717 W 6 A 240 V 50 Hz 717 W 3 A ...

Страница 19: ...g suspension only P N 91602003 Quick trigger clamp vertical hanging suspension only P N 91602007 Safety wire safe working load 50 kg P N 91604003 Related Items RUSH ELX Smoke fluid 4 x 5 liters P N 97120065 Ordering Information RUSH SM 650 EU P N 90480090 RUSH SM 650 US P N 90480095 Specifications are subject to change without notice For latest product specifications see www martin com Disposing o...

Страница 20: ......

Отзывы: