background image

User Manual

Setting Up

5

C h eck  vo l t ag e  se tt i n g

Important!

The controller’s voltage setting must match your local mains supply. 

The factory setting is printed on a label on the back of the controller. Check the
setting against the table below and rewire if necessary, following the instructions
on page 15. 

 

C O N N E C T I N G   T H E   S Y S T E M

You can use any DMX or Martin lighting controller to operate the RoboColor III
system. Control data is transmitted from the lighting controller via XLR data
cables to the data input on the RoboColor III controller. The RoboColor III
controller’s data output sends the data further to additional units: up to 32
RoboColor III systems can be connected on the same data link.

The RoboColor III can also be operated without a lighting controller in stand-
alone mode. In this mode, the system runs built-in sequences that are
automatically or music triggered depending on the mode selected. A special
master/slave feature allows several RoboColor III systems to synchronize (via the
data link) in stand-alone mode. These features are further described later. 

C o nn e ct   th e   Ro b o Co l o r   I I I   c on t r o l l er   to   t h e  h e ad s

The motor and lamp cables of each head must be connected to the RoboColor III
controller. Connect each pair of cables to sockets of the same group (1, 2, 3 or 4)
on the RoboColor III controller as shown below.

Important! 

To avoid damaging the controller, make sure that it is disconnected 
from AC power before connecting the heads. 

Mains Supply

Transformer Setting

210 - 240V

230V

240 - 255V

250V

Содержание RoboColor III

Страница 1: ...RoboColor III user manual P N 35000050 Rev B 1996 1999 Martin Professional A S Denmark...

Страница 2: ...sconnect the system from AC power if the lamp blows Allow the heads to cool for 15 minutes before installing a new lamp Do not illuminate surfaces within 30 cm 12 inches of the heads Do not place filt...

Страница 3: ...only to a RoboColor III controller UNPACKING The RoboColor III system includes the following items RoboColor III heads with Martin 150 W Metal Halide discharge lamps Mounting bracket Fittings for mou...

Страница 4: ...unded earthed The AC mains supply shall be have a fuse or circuit breaker and ground fault protection The controller may be supplied without a plug on the mains cable You will have to fit a plug that...

Страница 5: ...systems can be connected on the same data link The RoboColor III can also be operated without a lighting controller in stand alone mode In this mode the system runs built in sequences that are automa...

Страница 6: ...g adaptor such as P N 11820003 as shown below This adaptor connects pin 2 on one end to pin 3 on the other end and vice versa to correct the difference in polarity between the RoboColor III system and...

Страница 7: ...t unit on the link Use a 3 pin XLR male plug with a 120 resistor between pin 2 and 3 supplied with all Martin controllers Important Failure to use a termination plug can cause communication errors bet...

Страница 8: ...in tracking mode DMX mode 1 and 6 consecutive DMX channels in vector mode DMX mode 2 The factory default is DMX mode 1 Example 4 RoboColor III systems using DMX mode 1 may be addressed as follows Set...

Страница 9: ...69 49 533 565 597 5 9 65 693 6 5 757 789 7 4 3 3 4 3 74 6 438 46 49 534 566 598 5 65 694 6 6 758 78 7 3 4 3 4 3 43 75 7 439 46 4 3 535 567 599 5 663 695 6 7 759 78 7 3 4 4 3 4 3 44 76 8 43 46 4 4 536...

Страница 10: ...tarting on page 11 M A S T ER S L A V E O P ERA TIO N Master slave stand alone operation means that you can have one RoboColor III system master system acting as a controller when set to stand alone m...

Страница 11: ...e heads C O LO R S P LI T E F F E C T S By placing the color wheel between two adjacent colors color split effects can be achieved C O LO R S C R O L L IN G When switching from one color to another yo...

Страница 12: ...ols The RoboColor III controller should not require any maintenance Clean the optics 1 To access the optical components inside head remove the screws as shown and then lift and remove the bottom cover...

Страница 13: ...e lamp 1 Remove the 3 thumbscrews that secure the access plate of the lamp socket assembly at the rear of the head and withdraw the lamp socket assembly 2 Remove the old lamp from the socket 3 Holding...

Страница 14: ...tered in the reflector Pull the hot spot into the center of the field with small adjustments of one or more of the screws Note the Martin Metal Halide lamp is nearly as large as the reflector opening...

Страница 15: ...tting 1 Access the transformer by removing the top cover 2 On the transformer move the BROWN wire to the correct voltage terminal If the mains voltage is between 210 and 240 volt use the 230 volt tap...

Страница 16: ...is located inside the IEC mains input socket at the rear of the controller Use a small screwdriver to pry open the fuse holder and replace the fuse with one of the same size and rating The fuse ratin...

Страница 17: ...ome available Software can be supplied by your Martin dealer as P N 62122026 Please check with your Martin dealer to find out if the software upgrade requires any mechanical changes to the RoboColor I...

Страница 18: ...to the socket XL R PIN OUT If the RoboColor III is operated via a DMX controller you can change the XLR pin out to eliminate the need for phase reversing cables This can be done inside the RoboColor I...

Страница 19: ...6 150 151 165 166 180 181 184 185 189 190 194 195 199 200 204 205 209 210 214 215 219 220 224 225 229 230 234 235 239 240 255 Color Wheel Head 1 2 3 4 Blackout White White Color 1 Color 1 Color 2 Colo...

Страница 20: ...n RS 485 2 10 Stand Alone Sequence Auto trigger 1 2 10 Stand Alone Sequence Music trigger 2 3 10 Stand Alone Sequence Auto trigger Head 1 4 same color 1 2 3 10 Stand Alone Sequence Music trigger Head...

Страница 21: ...Data link not terminated with termination plug Insert termination plug in the last unit on the data link Incorrectly addressing DIP switch setting of the RoboColor III controller Ensure that all ligh...

Страница 22: ...onnected to RoboColor III controller Connect cables Remember to switch off the RoboColor III controller first The RoboColor III system appears to be completely dead no reset when switching on Mains fu...

Страница 23: ...tor 0 8 C O M P A TI B L E LA M P S Martin 150 W Metal Halide P N 97010107 Osram HTI 150 P N 97010108 GE CSS 150 P N 97010104 PH O T OM ET R I C D A TA Beam angle standard 17 Beam angle optional 25 TH...

Страница 24: ...0DUWLQ 3URIHVVLRQDO 26 Olof Palmes All 18 8200 Aarhus N Denmark Tel 45 8740 0000 www martin dk...