© Martin Engineering GmbH
21
M3735UK-09/15
Installation
5.3
Operation with loading
1. Remove all tools and fire protection covers from the installation
site and the conveyor belt.
2. Operate the conveyor system for one hour under load.
3. Shut off the conveyor belt system after the one-hour operation
under load, shut off the power supply and secure it against
unauthorised reactivation.
4. Check whether all of the fastening points are securely
tightened. Tighten any loose connections.
CAUTION! FLYING OBJECTS!
Forgotten tools or installation parts can fall off of the running
conveyor belt and cause minor injuries and property damage.
Always remove any tools from the installation site and conveyor
belt upon completion of the installation work before switching on
the power supply.
WARNING! RISK OF INJURY!
Body parts and/or clothing may get caught and pulled in by
rotating parts or by the moving conveyor belt.
Shut off the power supply to the conveyor system and its
accessories and secure it against unauthorised reactivation before
performing any installation or maintenance work.
Use warning signs!
CAUTION! RISK OF DAMAGE!
Never operate the fully tensed belt cleaner for longer than 15
minutes on the running unloaded conveyor belt. A risk of damage
due to overheating exists for the belt cleaner and/or the conveyor
belt.
Only operate the fully tensed belt cleaner on the running and fully
loaded conveyor belt.