Installation and setting up
13
P r i m i n g t h e m a c h i n e a f t e r f l u i d o u t
If the machine runs out of fluid it may not pump properly after refilling the fluid
due to airlocks in the fluid pipework.
To prime the machine, hold down the FOG button and keep the button held until
the fog output is strong and steady.
If the machine is left to run when out of fluid, damage will be caused to the pump
which may cause premature pump failure.
W h a t t h e s t a t u s l i g h t s m e a n
The red heat light on the remote control has the following meanings.
on
Machine is heating but is not yet up to operating
temperature
off
Machine is either ready to fire or not powered (check
mains switch light for status)
The red/green Heat / Ready lights on the top of the machine have the
following meanings.
HEAT+READY meaning
no lights
Machine is not powered
heat
Machine is heating but is not yet up to operating
temperature
heat + ready
Machine is heating and has reached minimum operating
temperature. Fog output level may be reduced while
heating
ready
Machine has finished heating and is at full operating
temperature