Display messages
27
D
ISPLAY
MESSAGES
B
Display readout
Appears if...
What to do
SRST (Serial reset)
...the fixture receives a reset command from
the controller.
To prevent accidental resets, disable
command. See page 13.
LERR (Lamp error)
.... the lamp doesn’t ignite within 10 minutes of
receiving the ‘Lamp ON’ command. Likely
reasons are a missing or defective lamp, or
insufficient AC voltage.
Check the lamp and check that the
mains setting of the fixture matches the
mains supply.
MERR (Memory error)
...the EEPROM memory cannot be read.
Contact Martin technician for assistance.
CSER (Check-sum error)
...a software upload is not successful.
Upload software again, see page 23.
****
... there is no communication between the
control module and motherboard. This readout
appears briefly when switching on the fixture.
Check fuses on motherboard and
replace accordingly.
Check that ribbon cable between control
module and motherboard is connected
properly.
ShER (Short error)
... the fixture detects that the lamp is ON but
no ‘Lamp ON’ command has been received.
This can occur if the lamp relays are stuck in
the ON position or if the lamp-power feedback
circuit has failed. You can still operate the
fixture but may not be able to remotely switch
off the lamp.
Contact Martin technician for assistance.
Hot (Hot lamp)
... you attempt to strike the lamp within 8
minutes after having switched it off. The fixture
will store the ‘Lamp ON’ instruction and strike
the lamp once the 8 minutes have elapsed.
Wait until the lamp strikes.
bTER (Base temperature error)
HTER (Head temperature error)
...there is a malfunction in the base or head
temperature sensing circuit.
Contact Martin technician for assistance.
FbEP (Feedback error pan)
FbET (Feedback error tilt)
FbER (Feedback error pan/tilt)
...pan (FbEp), tilt (FbET) or both (FbER)
feedback circuits are malfunctioning. It will still
be possible to operate the fixture, though it
goes into a “safe” mode where maximum
speed is reduced, thus preventing the fixture
from losing track of its home position (losing
step).
Contact Martin technician for assistance.
PAER (Pan time-out)
TIER (Tilt time-out)
CYER (Cyan time-out)
MAER (Magenta time-out)
YEER (Yellow time-out)
CTER (CTC time-out)
...the microswitch indexing circuit
malfunctions. The effect defaults to a
mechanical stop and continues to work
normally.
Contact Martin technician for assistance.
DIER (Dimmer time-out)
COER (Color time-out)
bSER (Beam shaper 1 time-out)
...the magnetic-indexing circuit malfunctions.
After the time-out, the effect stops in a random
position.
Contact Martin technician for assistance.
Содержание MAC 600 NT
Страница 1: ...MAC 600 E NT user manual...