14
MAC 600 (E) NT
Tests and readouts
The following readouts and tests are available from the control panel.
T o c al i b r a te te mper a tu r e sens or s
The temperature sensors are calibrated at the factory. Use this procedure if you suspect the calibration is faulty.
1
Turn off the fixture for 4 hours to allow it to cool to room temperature.
2
Measure the room temperature in Celsius. (To convert F° to C°, subtract 32° and multiply by 0.555.)
3
Power up the unit and allow it to reset.
4
Press [MENU] and [
↓
] and hold until “25” is displayed.
5
Scroll to the room temperature and press [ENTER].
Function
Path
Options
Readout or effect
Usage counters
T I M E /
P o H
Total hours of operation since fabricated.
R P o H
Hours of operation since counter reset. To reset, display
counter and press [
↑
]
for 5 seconds.
L A
H
Total hours of operation with lamp on since fabricated.
R L A H
Lamp hours since counter reset. Reset when relamping to
track lamp life. To reset, display counter and press [
↑
]
for 5
seconds.
L S T R
Total number of lamp strikes since fabricated.
R S T R
Number of lamp strikes since counter reset. To reset, display
counter and press [
↑
]
for 5 seconds.
DMX readout
d M X L /
S T C O
Decimal value of the DMX start code. The start code must be
0 for the MAC 600 (E) NT to function properly.
C H 0 . . C H 1 4
DMX value (from 0 - 255) received for each channel. Note
that the channel number is 1 less than it is in the DMX
protocol.
Software versions
V e r /
C P U
CPU firmware version. Updates can be uploaded.
F E B A
Feedback circuit firmware version.
d I S P
Display circuit firmware version.
Temperature readout
S P E C / T E M P /
H E A d
Head temperature in Celsius.
Temperatures below 25° C are
shown as
- 2 5
; temperatures above 100° C are shown as
+ 1 0 0
.
b A S E
Base temperature in Celsius.
Temperatures below 25° C are
shown as
- 2 5
; temperatures above 100° C are shown as
+ 1 0 0
.
Tests
T S E Q
R U N
Run a general test of all effects
S P E C / P C b T
T 1 - T 3
Run three tests of the circuit board.
For service use only.
S P E C / F T S T /
W T S T
Run an quality control effects test
M T S T
Run a quality control movement test
S P E C / F T S T /
S T S T
d I M
Run a quality control dimmer sensor test
C O L
Run a quality control color wheel sensor test
b S
Run a quality control beam shaper sensor test