![Martin M3776UK Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/martin/m3776uk/m3776uk_operators-manual_1732567013.webp)
© Martin Engineering GmbH
13
M3776UK-05/10
Installing controller
4.3
Programming controller
The control programme is stored in the controller upon delivery and should
not be changed. The programme can be adapted by changing the following
time variables (Times shown in italics are optional):
• T01 Monitoring filling time container 1 - changeable
• T06 Delay time of next cycle - changeable
• T13 Delay time extending slave cylinder - changeable
The following chart emphasises the programme sequence with the pro-
grammable time variables:
Figure 5: Programme sequence
Master cylinder extended - T05
Master cylinder retracted - T04
Master cylinder
Slave cylinder retracted - T13
Slave cylinder extended - T03
Slave cylinder
Pressure has been achieved
Hold pressure for approx. 3 s
Slave cylinder extended
Master cylinder retracted
approx. 2-3
approx. 2-3
Pressure switch
Fill pressure reservoir
AUTOMATIC (external)/
1
0
1
0
1
0
1
0
1
0
Work steps
Time