14
LC Plus user manual
Installing power cable connectors
Installing Amphenol connectors
The Amphenol C016 ecomate series power cable connectors used with the LC Plus accept power cable
from 6 mm (0.24 in.) to 9 mm (0.35 in.) diameter when fitted with a standard cable gasket, or from 9 mm
(0.35 in.) to 12.5 mm (0.5 in.) diameter when fitted with an optional heavy gauge cable gasket.
If you need to install an Amphenol C016 series cable connector on a power cable for connection to an LC
Plus panel:
1. Ensure that the power cable is UL-listed, 16 AWG minimum in North America or 3 x 1.5 mm
2
minimum
in other regions, 3-conductor Hypalon or neoprene rubber-jacket type, approved for a current of 16 A
and a temperature of 90° C (194° F) minimum.
2. Obtain a female cable connector (Amphenol C016 20 D 003 100 12) for power input or a male cable
connector (Amphenol C016 20 H 003 100 12) for power out/throughput.
3. See Figure 9. Pass the cable through the cable nut, correct gasket for the cable diameter, clamping ring
and back shell.
4. Strip 18-19 mm (0.70-0.75 in.) of cable jacket and then strip 7-8 mm (0.27-0.31 in.) of insulation from
each conductor (as indicated for screw contacts with internal cable retention in Figure 9). Twist the bared
strands at the end of each conductor to strengthen them.
5. Fasten the conductors in the cable into the screw terminals in the male or female contact insert as
follows:
When installing an Amphenol C016 series power connector in a single-phase system:
- Fasten the green/yellow ground (earth) conductor in the screw terminal marked
Drain
or
.
- Fasten the blue neutral conductor in the screw terminal marked
2
.
- Fasten the brown live conductor in the screw terminal marked
1
.
- Do not connect anything to the terminal marked
3
.
-OUNTING)NSTRUCTIONSTRAIGHTCABLECONNECTOR
ADDITIONALLY
INCLUDEDGASKET
CABLENUT
TIGHTENINGTORQUE
.M
TIGHTENINGTORQUE.M
-OUNTING)NSTRUCTIONS
B
A
3TRIPPING,ENGTHS
3CREWCONTACTS
WITHINTERNALCABLERETENTION
WITHOUTINTERNALCABLERETENTION
3OLDERCONTACTS
WITHINTERNALCABLERETENTION
WITHOUTINTERNALCABLERETENTION
#RIMPCONTACTS
nMM
nMM
WITHINTERNALCABLERETENTION
WITHOUTINTERNALCABLERETENTION
0%MM ENDSPLICERECOMMENDED
-EASUREB
-EASUREA
CLAMPINGRINGWITHMOUNTEDGASKET
BACKSHELL
TIGHTENINGTORQUE
.M
INTERNAL
STRAINRELIEF
MALECONTACT
INSERTWITH
LOCKINGRING
FEMALECONTACT
INSERTWITH
LOCKINGRING
Figure 9: Amphenol power cable connector assembly instructions
Content in this illustration is copyright ©Amphenol-Tuchel Electronics GmbH and used by permission. These illustrations may not
be reproduced in any form without the written permission of Amphenol-Tuchel Electronics GmbH.