![Martin Cyclo Directional IP65 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/martin/cyclo-directional-ip65/cyclo-directional-ip65_user-manual_1732838031.webp)
Stand-alone operation
31
Single stand-alone operation
In single stand-alone operation, a luminaire runs its own program
independently of all other luminaires. To do this, the luminaire must be set
as a master.
Activating single stand-alone operation
To activate single stand-alone operation:
1. Set DIP switch pin 10 to ON (switches from DMX to stand-alone mode).
2. Set DIP switch pin 9 to OFF (activates master mode).
3. Set DIP switch pin 8 to OFF (activates stand-alone mode)
4. Program the luminaire using DIP switch pins 1 - 7 (see table on page 29).
Master/slave stand-alone operation
Important!
Do not set more than one luminaire on a data link as master, and
do not set a luminaire as master on a data link with a DMX
controller. Doing so may cause damage to the electronics that
is not covered by the product warranty.
In master/slave stand-alone operation, one master luminaire transmits a
synchronizing signal to slave luminaires over the data link each time it starts
a new action. Slave luminaires start their next programmed action when
they receive this signal from the master luminaire. Programs can be
identical on all luminaires, or luminaires can – subject to certain practical
constraints – run programs that are synchronized but not identical.
Note that each luminaire follows the program set on its own DIP switch as
described in the table on page 29.
Note also that colors are always displayed in the order: white
→
red
→
green
→
blue.
This means for example that if white is activated, it will always be first in the
program. If white is not activated but red is activated, red will be first in the
program.
More sophisticated light shows can be programmed using a DMX controller
(see “
The synchronization signal used by the Cyclo IP65 Directional is identical to
that used in other Cyclo luminaires with the same number of tubes, allowing
these products to be combined in master/slave operation on one data link.
However, Cyclos with different numbers of tubes cannot be mixed in master-
Содержание Cyclo Directional IP65