![Martin Cyclo Directional IP65 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/martin/cyclo-directional-ip65/cyclo-directional-ip65_user-manual_1732838019.webp)
Installation
19
permitted RCD trip current ratings are normally stated in national
electrical and building codes.
3. Install surge current-resistant RCDs.
Connecting to power
A screw clamp is provided for connecting the luminaire to the power cable’s
earth conductor, and a block of spring-loaded clamp terminals are provided
for connecting the luminaire to the power cable’s live and neutral power
conductors.Some common color-coding systems for power wiring are given
below:
To connect to AC power:
1. Ensure that power cannot be applied to the cable during installation.
2. Open the connections compartment as described in “
3. Pass the power input cable through a cable gland as described in “
” on page 15 so that approximately 20 cm (8 in.) of cable is free
inside the luminaire, and prepare the end of the cable for connection.
4. See Figure 11. Four spring-loaded terminals marked
L1
,
L2
,
L3
and
N
and one screw clamp marked
are provided for power cable
connection. The terminals marked
L2
and
L3
are not used to supply
power to the luminaire and are provided only to allow phase conductors
to be connected if power is supplied from a 3-phase system (see
“
Connecting to a 3-phase system
Wire (EU)
Wire (US)
Pin
Marking on luminaire
brown
black
live
L1
blue
white
neutral
N
yellow/green
green
ground
Table 1: Power cable color-coding systems