manualshive.com logo in svg
background image

GB

- 4 -

User manual

You are now the owner of a dog control
system from the DYNAVET range. We
thank you for your confidence in our pro-
ducts.

Before using the Zone Protector®
containment system, we recommend you
carefully read the instructions in this user
manual concerning the setting-up, main-
tenance and repair of the system, and the
training of your dog.

Make sure you keep it in a safe place for
further reference.

We also recommend you watch the DVD
provided with the kit.

CONTENTS  

1. Introduction and precautions  . p. 4
2. Contents of the kit. . . . . . . . . . p. 4
3. Operating principle of the JetCare

System Free Zone®. . . . . . . . . p. 4

4. Setting up the system  . . . . . . p. 4
5. Training your dog . . . . . . . . . . p. 6
6. Maintenance of the system . . . p. 6
7. Repair of the system in the 

event of malfunction . . . . . . . . p. 6

8. FAQ . . . . . . . . . . . . . . . . . . . . . p. 7

1. Introduction

and precautions

The Zone Protector® dog containment
system is designed to keep your unres-
trained dog safely inside an area you have

pre-determined. In this way you can
contain your dog or keep it away from
inappropriate areas.

CAUTION

Zone Protector® is not a physical barrier.
It is a collar-mounted device that uses a
radio-controlled spray burst to train your
dog not to leave a pre-determined area.
Prior training repeated at regular intervals
is essential for the system to work to best
effect.
We strongly advise you not to use this
device with a pet that could be dangerous
for others if it were to leave the contain-
ment area.
DYNAVET cannot be held liable for any
injury, damage, financial loss or indirect
adverse effects due to your pet leaving the
area controlled by Zone Protector®.

2. Contents of the kit

Your Zone Protector® kit contains:

- A transmitter unit with a 2

3

0 V mains

power supply.

- A collar receiver designed to fit most

sizes and breeds of dog.

- An adjustable collar strap.
- A 6V lithium battery.
- A disc to open the battery compartment

of the collar receiver.

- A 75 ml odourless refill.
- A 100 m reel of antenna wire.
- A set of 25 boundary flags.
- An user manual.
- A DVD showing installation and use.
- A guarantee card

.

 

Diagram of transmitter unit

A - Control knob
B - Green light

Diagram of collar receiver

A - Spray nozzle
B - Filling valve
C - Battery access
D - White background to check liquid level

TECHNICAL DATA

Transmitter unit

- 2

3

0 V mains power supply

- Not waterproof
- Size 150 x 94 x 60 mm

Collar receiver

- Power:

 

1 6V lithium battery

- Immersion-proof
- Weight 70 g empty (with battery),

 

86 g

in use 

- Size 60 x 47 x 36 mm
- Liquid volume 16 g

 

Antenna wire

- Diameter 0.75 mm
- Length 100 m

Refill

- Volume 75 ml net

3. Operating principle of

the Zone Protector®

The Zone Protector® system has three
main component parts: a mains-powered
transmitter unit, a collar receiver equipped
with a spray actuator, and a boundary
antenna wire.

The containment area where you want
your dog to stay is determined by laying
out the antenna wire, on or under the
ground or attached to an existing fence. A
low frequency radio signal from the trans-
mitter is sent out by this wire and picked
up by the collar receiver. The range of the
signal (i.e. the distance from the boundary
wire to reach the receiver) can be set to a
maximum of 6 m from the wire using the
control knob on the transmitter unit.

When your dog comes within range of the
boundary signal the collar receiver strap-
ped to its neck makes a warning beep. If
the dog does not move away immediately
it receives a rapid series of spray bursts
directed at its muzzle. These sprays cease
as soon as the dog moves away from the
boundary.

These perfectly harmless sprays are desi-
gned to surprise the dog and deter it from
moving closer to the boundary: the surpri-
se effect of the spray is due to the simul-
taneous stimulation of three of the 
animal’s senses: hearing (the sound of the
spray), sight (the spray mist) and touch
(cold wet contact of the spray).

4. Setting up the system

To install your system conveniently we
recommend you have the following tools
and materials to hand:
- A straight-edged spade or turf-cutter to

bury the wire.

- Wire strippers for connecting the wire to

the transmitter.

- Electrical insulating tape and sealant to

connect up the wires and keep them

twisted together when required.

- Power masonry cutting disc if you need

to run the wire through concrete, and
silicone-type sealant to fill the resulting
grooves.

- Flexible conduit or PVC hose for under-

water wire runs.

Step 1: Draw a ground plan of the
authorised area

The first step is to draw a ground plan for
the system that shows the shape of the
containment area, the path of the bounda-
ry wire, and the location of the transmitter,
which must be indoors.

Draw the ground plan of the containment
area you want on a sheet of squared
paper.

N.B

The transmitter sends a signal up to 6 m
on either side of the boundary wire. Make
sure you leave your dog enough room to
move freely inside the area. The signal
range is set using the control knob, which
goes from minimum to 6 m.

Examples of installation plans

Plan A
Classical whole garden boundary 

Plan B
Restriction to part of the garden

A

B

D

C

A

B

DYNAVET by Martin Sellier

51 rue Chappe

63051 CLERMONT-FERRAND CEDEX 2 

Tel . +33(0) 4.73.42.25.50

Fax . +33(0) 4.73.62.81.72

www.martinsellier.com

The collar must not be discarded 

with other waste: it should be 

discarded by selective waste 

collection for reclamation or 

recycling. Be sure to observe all 

applicable regulations in your 

country concerning electrical and 

electronic waste. 

Old  batteries  must  be  discarded 

in  compliance with the selective 

waste procedure in your area.

WARNING  !

There is a risk of explosion if the 

battery is replaced by the wrong 

type of battery.

RECYCLING

Hereby, DYNAVET BY MARTIN SELLIER, 
declares that the Zone

 Protector

  device  is 

in  compliance  with  the essential 
requirements  and  other  relevant 
provisions  of  Directive 1999/5/EC.
The  statement  of  compliance  is  available in 
the  appendix reference 062252.

Содержание Dynavet Zone Protector

Страница 1: ...062247 02 www martinsellier com Images non contractuelles Non contractual pictures ...

Страница 2: ......

Страница 3: ...e Protector 16 I Educare il propio cane con Zone Protector 20 E Educar a su perro con Zone Protector 24 P Educar o seu cão com Zone Protector 28 DA Opdrag din hund med Zone Protector 32 N Bruksanvisning for Zone Protector 36 FIN Kouluta koirasi Zone Protector 40 S Träna din hund med Zone Protector 44 GR Εκπαιδεύοντας τον σκύλο σας µε το Zone Protector 48 ...

Страница 4: ...er the ground or attached to an existing fence A low frequency radio signal from the trans mitter is sent out by this wire and picked up by the collar receiver The range of the signal i e the distance from the boundary wire to reach the receiver can be set to a maximum of 6 m from the wire using the control knob on the transmitter unit When your dog comes within range of the boundary signal the co...

Страница 5: ...fill it Use the disc provided to unscrew the lid of the battery compartment Slide the battery into the compartment end first The end must be visible when the battery is in place as shown on the battery polarity label on the back of the collar Use the disc to screw the lid of the bat tery back in pressing down lightly on the battery Proper closure of the battery compartment is necessary to keep the...

Страница 6: ...u Point the metal nozzle of the refill down wards Push the refill nozzle into the filling valve keeping the refill canister upright Press down hard for a few seconds Release the pressure to let out remai ning air Repeat the operation several times until the reservoir is full You can check the liquid level through the transparent wall by tilting the unit CAUTION Never carry out the filling operatio...

Страница 7: ... wires Caution each broken part must be connected as follows Obtain a screw type electrical wire connector First strip the ends of the wire to be connected Insert the stripped wire ends into the connector and secure them with the screws Pull gently to make sure they are secure Apply a sealant e g silicone inside and all around the connector When the sealant is hard wrap the wires and the connector...

Отзывы: