WARNING

THIS EQUIPMENT MUST BE OPERATED WITH A 

3–

CONDUCTOR

GROUNDED AC POWER RECEPTACLE

.

  FAILURE TO USE A 

PROPERLY GROUNDED RECEPTACLE MAY RESULT IN IMPROPER
OPERATION OR A SAFETY HAZARD

.

LIMITED WARRANTY

The Seller warrants that, at the time of shipment, the
products manufactured by the Seller are free from de-
fects in material and workmanship. The Seller’s obliga-
tion under this warranty is limited to replacement or re-
pair of such products which are returned to Marti at its
factory, transportation prepaid and properly insured,
provided:

a.  Notice of the claimed defect is given to Marti with

in one (1) year  [two (2) years for STL systems] from
date of original shipment and goods are returned in ac-
cordance with Marti instructions.

b.  Equipment, accessories, tubes and batteries not

manufactured by Marti are subject to only such adjust-
ments as Marti may obtain from the supplier thereof.

c. This warranty does not apply to equipment which

has been altered, improperly handled, or damaged in
any way.

The Seller is in no event liable for consequential dam-
ages, installation cost or other costs of any nature as a
result of the use of the products manufactured or sup-
plied by the Seller, whether used in accordance with in-
structions or not.

This warranty is in lieu of all others, either expressed or
implied. No representative is authorized to assume for
the Seller any other liability in connection with Seller’s
products.

 

MAILING 

&

 SHIPPING ADDRESS

:

M

ARTI

 

Electronics

4100 North 24th Street

Quincy, Illinois 62301

The United States of America

COPYRIGHT NOTICE

2000 All Rights Reserved

Marti Electronics

No part of this manual may be reproduced, transmitted,
transcribed, stored in a retrieval system , or translated
into any language, natural or computer, in any form or
by any means, without the prior written permission of
Marti Electronics.

Artwork depicting circuitry in this manual is protected
by copyright laws.

Information in this manual is subject to change without
notice and does not represent a commitment on the part
of Marti Electronics.

Marti Electronics may make improvements and/or
changes in this manual or in the product described here-
in at any time.

This product could include technical inaccuracies or 
typographical errors.

PHONE NUMBERS:

Sales (817) 

735–8134

Sales FAX

(817) 735–9340

Service

(217) 224–9600

Service Fax

(217) 224–9607

Содержание STL-10A

Страница 1: ...MARTI ELECTRONICS STL TRANSMITTER MODEL STL 10A October 2001 597 9500...

Страница 2: ...D ADJUSTMENT 7 OPERATION 7 SWITCH AND METER FUNCTIONS 7 TRANSMIT OFF SWITCH AND LED 7 FORWARD REFLECTED SWITCH AND RF POWER METER 8 PEAK MODULATION METER 8 TEST METER 8 PRE EMPHASIS SWITCHES 9 FREQUEN...

Страница 3: ...JUST 17 REVERSE POWER METER ADJUST 17 PA CURRENT ADJUST 18 FREQUENCY MEASUREMENT 18 STL 10A PARTS LIST 22 STL 10A SCHEMATICS 33 LIST OF ILLUSTRATIONS FIGURE NO TITLE PAGE NO 1 STL 10A TRANSMITTER 1 2...

Страница 4: ...on cost or other costs of any nature as a result of the use of the products manufactured or sup plied by the Seller whether used in accordance with in structions or not This warranty is in lieu of all...

Страница 5: ...st Inter city relay for linking two or more broadcast facilities Multi relay system for radio network distribution Communications link between satellite earth station and broadcast facilities Data and...

Страница 6: ...2 FIGURE 2 STEREO STL SYSTEM BLOCK DIAGRAM 702 058 COPYRIGHT 2000 MARTI ELECTRONICS...

Страница 7: ...technology and is manufactured in modern efficient facilities under high quality control standards STL 10A System Specifications Freq Range MHz Transmitter Maximum Power Maximum Deviation Receiver Re...

Страница 8: ...S Precision Peak hold Bar Graph Modulation Meter Illuminated RF Wattmeter indicates Forward Power Reflected Power Test Meter reads PA Current Subcarrier Level 13 5 Volt Supply and RF Drive 1 RF Drive...

Страница 9: ...ed rack cabinet Do not locate solid state equipment in a rack above tube type equipment which produces high temperatures Problems can also be avoided by locating this unit away from other equipment wh...

Страница 10: ...rer s instructions carefully If no instructions were included with the antenna call or write the antenna manufacturer for instructions Errors are frequently made in assembly of the RF feed dipole elem...

Страница 11: ...ng in a signal level of only a fraction of the major lobe signal This error can be avoided only by swinging the antenna through a large angle so that all lobes are evaluated and the major lobe clearly...

Страница 12: ...modulation composite or mono mode The five highest LED s 100 to 250 have a peak hold feature which will display an instantaneous peak value for one second This is a valuable feature when dealing with...

Страница 13: ...75 micro second pre emphasis Received signal levels less than full quieting may produce a difference of as much as 13 dB between flat and 75 micro second pre emphasis FREQUENCY MEASUREMENT The RF out...

Страница 14: ...the de emphasis curve selected At 15 KHz there is sufficient level to operate most modern distortion analyzers Distortion levels should be within specifications If distortion is out of specs check sys...

Страница 15: ...frequency ranging from 445 to 480 MHz is fed into the 10 15C PA Interface board 800 374B The purpose of this board is to double the incoming frequency amplify the doubled frequency and filter out all...

Страница 16: ...12 COPYRIGHT 2000 MARTI ELECTRONICS FIGURE 3 FCC EMISSION PROFILE 500 KHZ CHANNEL DRAWING...

Страница 17: ...13 FIGURE 4 FCC EMISSION PROFILE 200 KHZ CHANNEL DRAWING COPYRIGHT 2000 MARTI ELECTRONICS...

Страница 18: ...unter to the sampling attenuator or J5 the FREQUENCY TEST JACK Operate the CONTROL switch to TRANSMIT 1 Measure the bias voltage at TP test point of modulator circuit board 800 195 using digital dc vo...

Страница 19: ...________________________ kHz Total DC Current __________________________ amperes TEST POINT READINGS TP 1 __________ 0 15 V dc 0 60 V dc TP 2 __________ 0 70 V dc 1 90 V dc TP 3 __________ 0 50 V dc 1...

Страница 20: ...be to chassis ground Operate the CONTROL switch to TRANSMIT A minimum of 0 25 volts should be indicated If not refer to MODULATOR CIRCUIT BOARD ADJUSTMENTS in the preceding text 2 Move the meter negat...

Отзывы: