Marti Electronics STL-10A Скачать руководство пользователя страница 14

10

NOISE.

Noise measurements should be made first, since high noise levels will influence distortion readings.  Also ground
loops in the audio oscillator to transmitter connections and distortion analyzer to receiver connections must be 
resolved before testing begins. The influence of high RF fields upon the test equipment must be determined and 
corrected before accurate measurements can be made. NOTE: NOISE AND DISTORTION MEASUREMENTS
ARE MADE WITH SUBCARRIER AND REMOTE CONTROL INPUT SIGNALS REMOVED.  System signal to
noise ratio is determined while modulating the transmitter 100% at 400 Hz. A level of +8 dBm across the balanced
audio input terminals of TB–1 will produce a reading of 100% modulation on the “PEAK MODULATION” 
indicator. Set Receiver “PGM LEVEL ADJ” pot for +10 dBm output into the distortion analyzer. If the distortion
analyzer has a high impedance input, add a 600 ohm load resistor to match the receiver. Est10 dBm on the
audio voltmeter of the analyzer as the reference level for 100% modulation. Next, remove the audio signal from the
transmitter input and measure noise level below reference (100% modulation). This reading should compare with
that published under 

SYSTEM SPECIFICATIONS

 in this manual.

DISTORTION.

Harmonic distortion is usually measured at 100% modulation and at several frequencies. If pre–emphasis processing
is used in the transmitter with corresponding de–emphasis in the receiver, it is normal for available audio level at the
receiver to drop with increasing frequency according to the de–emphasis curve selected. At 15 KHz, there is 
sufficient level to operate most modern distortion analyzers. Distortion levels should be within specifications. If 
distortion is out of specs, check system noise, check for test equipment ground loops, RFI, and transmitter/receiver
operating frequency. If either unit is off frequency, the FM modulation sidebands are not centered within the IF filter
bandpass, which can cause audio distortion.

FREQUENCY RESPONSE.

If the STL–10A System is switched to flat processing, frequency response can be measured as if the signal were be-
ing sent over straight wires. If pre–emphasis processing is used (especially 75 micro–seconds) allowance must be
made in the transmitter audio input level to prevent over–modulation at test frequencies above 400 Hz. The simplest
and fastest method is to set the transmitter audio input level for 100% modulation at 400 Hz, then attenuate this level
20 dB.   Set receiver output level to –10 dBm as the reference, then sweep the audio band for response. Response
should be within limits published in the 

SYSTEM SPECIFICATIONS.

STL–10A THEORY OF OPERATION.

Refer to the STL–10A block diagram in the DRAWINGS AND PARTS LIST section for the following discussion.

POWER SUPPLY 800–168.

Power supply circuit board 800–168 contains filter capacitor C5, and reverse polarity protection diodes D5, D6 and
D7.  The unregulated output voltage of this supply is 17–20 volts.  The voltage is supplied from bridge rectifier
D1–4 on circuit board 800–168.

INPUT/OUTPUT FILTER 800–193A.

Radio–frequency filters are installed on all input/output circuits connected to ACCESSORY connector J4, as well as
the AC line input.

CONTROL BOARD 800–197.

Applies an operating voltage to the unit.

Содержание STL-10A

Страница 1: ...MARTI ELECTRONICS STL TRANSMITTER MODEL STL 10A October 2001 597 9500...

Страница 2: ...D ADJUSTMENT 7 OPERATION 7 SWITCH AND METER FUNCTIONS 7 TRANSMIT OFF SWITCH AND LED 7 FORWARD REFLECTED SWITCH AND RF POWER METER 8 PEAK MODULATION METER 8 TEST METER 8 PRE EMPHASIS SWITCHES 9 FREQUEN...

Страница 3: ...JUST 17 REVERSE POWER METER ADJUST 17 PA CURRENT ADJUST 18 FREQUENCY MEASUREMENT 18 STL 10A PARTS LIST 22 STL 10A SCHEMATICS 33 LIST OF ILLUSTRATIONS FIGURE NO TITLE PAGE NO 1 STL 10A TRANSMITTER 1 2...

Страница 4: ...on cost or other costs of any nature as a result of the use of the products manufactured or sup plied by the Seller whether used in accordance with in structions or not This warranty is in lieu of all...

Страница 5: ...st Inter city relay for linking two or more broadcast facilities Multi relay system for radio network distribution Communications link between satellite earth station and broadcast facilities Data and...

Страница 6: ...2 FIGURE 2 STEREO STL SYSTEM BLOCK DIAGRAM 702 058 COPYRIGHT 2000 MARTI ELECTRONICS...

Страница 7: ...technology and is manufactured in modern efficient facilities under high quality control standards STL 10A System Specifications Freq Range MHz Transmitter Maximum Power Maximum Deviation Receiver Re...

Страница 8: ...S Precision Peak hold Bar Graph Modulation Meter Illuminated RF Wattmeter indicates Forward Power Reflected Power Test Meter reads PA Current Subcarrier Level 13 5 Volt Supply and RF Drive 1 RF Drive...

Страница 9: ...ed rack cabinet Do not locate solid state equipment in a rack above tube type equipment which produces high temperatures Problems can also be avoided by locating this unit away from other equipment wh...

Страница 10: ...rer s instructions carefully If no instructions were included with the antenna call or write the antenna manufacturer for instructions Errors are frequently made in assembly of the RF feed dipole elem...

Страница 11: ...ng in a signal level of only a fraction of the major lobe signal This error can be avoided only by swinging the antenna through a large angle so that all lobes are evaluated and the major lobe clearly...

Страница 12: ...modulation composite or mono mode The five highest LED s 100 to 250 have a peak hold feature which will display an instantaneous peak value for one second This is a valuable feature when dealing with...

Страница 13: ...75 micro second pre emphasis Received signal levels less than full quieting may produce a difference of as much as 13 dB between flat and 75 micro second pre emphasis FREQUENCY MEASUREMENT The RF out...

Страница 14: ...the de emphasis curve selected At 15 KHz there is sufficient level to operate most modern distortion analyzers Distortion levels should be within specifications If distortion is out of specs check sys...

Страница 15: ...frequency ranging from 445 to 480 MHz is fed into the 10 15C PA Interface board 800 374B The purpose of this board is to double the incoming frequency amplify the doubled frequency and filter out all...

Страница 16: ...12 COPYRIGHT 2000 MARTI ELECTRONICS FIGURE 3 FCC EMISSION PROFILE 500 KHZ CHANNEL DRAWING...

Страница 17: ...13 FIGURE 4 FCC EMISSION PROFILE 200 KHZ CHANNEL DRAWING COPYRIGHT 2000 MARTI ELECTRONICS...

Страница 18: ...unter to the sampling attenuator or J5 the FREQUENCY TEST JACK Operate the CONTROL switch to TRANSMIT 1 Measure the bias voltage at TP test point of modulator circuit board 800 195 using digital dc vo...

Страница 19: ...________________________ kHz Total DC Current __________________________ amperes TEST POINT READINGS TP 1 __________ 0 15 V dc 0 60 V dc TP 2 __________ 0 70 V dc 1 90 V dc TP 3 __________ 0 50 V dc 1...

Страница 20: ...be to chassis ground Operate the CONTROL switch to TRANSMIT A minimum of 0 25 volts should be indicated If not refer to MODULATOR CIRCUIT BOARD ADJUSTMENTS in the preceding text 2 Move the meter negat...