F
D
G
H
S
B
K
A
C
Product Installation
NOTE:
This product must be installed by a licensed electrician.
NOTE:
For best performance install at a height between 2 and 2.5 metres.
1.
Ensure the Mains Supply is switched ‘OFF’.
2.
wired to its own wall switch.
3.
Remove the mounting plate ‘A’ from light body ‘B’ by unscrewing the front screws ‘C’.
4.
Drill two holes in the wall using the mounting holes ‘D’ on the mounting plate ‘A’ as a template.
Note: exercise caution to avoid drilling into existing electrical wiring.
5.
Feed mains supply cable through the wall and weatherproof holes as appropriate. Pierce the rubber
grommet ‘G’ with a screwdriver and pass the mains supply cable through.
Connect the Live (L), Neutral (N) Earth(E) according to the markings on the terminal block ‘H’.
6.
7.
8.
9.
Apply silicone if required around the base plate and grommet ‘G’ to maintain IP rating.
10. Loosen the Screw in knuckle ‘K’ and angle the light head into desired direction, then
Light heads should not be faced above the horizontal.
11. Reconnect the mains supply.
12. Turn on the security light.
•
Do not direct the heads upwards above horizontal.
•
Always operate the sensor with sensor knobs
facing downwards.
www.martecaustralia.com.au | 02 8778 7500 | [email protected]
Page 8