PREHEAT: 

 
1.  The  controller  will  stay  in  preheat  mode  ("PHt")  for  the  entire  preheat  period  (preheat  time 

parameter) even though both heaters (top and bottom) have reached set points before the end 
of that period.  If the controller is inadvertently turned OFF and back ON, the preheat period can 
be  bypassed  by  a  3  second  press  of  the  down  arrow button only if both heaters are within the 
allowed differential temperature set points (preheat bypass temperature parameter). 

 
2.  After preheat, the controller goes into idle mode "---".  At this time, any timer can be started. 
 

HOLDING TIME CYCLES: 

 

1.  To start a cycle, press a timer start/stop button.  The display will show the holding time value in 

minutes  and  starts  the  countdown.    The  LED  bars  for  that  timer  channel  will  then  light  steady 
green. 

 
2.  When the timer reaches the pre-alert value, the display will then alternate between showing the 

remaining time and "drP" for DROP, the LED bars will start flashing and a beeping will start.  The 
user then has to acknowledge the pre-alert by a press of the timer start/stop button.  The display 
will then  flash  the  remaining  time  for  the  rest of the cycle, the LED bars will go back to steady 
and the beeping will stop. 

 

3.  When the timer reaches the "000" value, the display will flash "000", the LED bars will flash red 

and the beeping will start until the user acknowledges the end of the cycle by pressing the timer 
start/stop button.  The timer will then go back to idle mode "---", the led bars will turn OFF and 
the beeping will stop.   

 

4.  Any holding cycle can be cancel at any time by a 

U

3 second press

U

 of the timer start/stop button. 

 

5.  If  at  any  time  during  normal  operation, 

one  heater’s  temperature  is  falling  or  rising  out  of  the 

allowed differential from set point (ready mode differential parameter), the displays will alternate 
between current mode and "LO" or "HI" to alert the user that 

the heater’s temperature is too low 

or too hi.  This should remain until the heaters are back within the allowed differential. 

 

CURRENT TEMPERATURES DISPLAY: 

 

1.  To view the heaters current temperature, press and hold the temperature button for 3 seconds.  

The display will then alternate between "toP" for top heater and its current temperature value. 

 

2.  To view the bottom heater current temperature, press the temperature button again.  The  

 
display will then alternate between "bot" for bottom heater and its current temperature value. 

 

3.  A press of the temperature button will cycle between top and bottom current temperatures. 

 

4.  To  exit  temperature  view  mode  and  return  to  previous  mode,  press  and  hold  the  temperature 

button. 

 
 
 
 
 

Содержание DH5F-333ARB

Страница 1: ...per and lower flat plate heating surfaces This eliminates the need to clean intricate calrod wire and reflector assemblies The cabinet can accommodate up to two 1 3 size pans 2 deep per deck The cabin...

Страница 2: ...MILD NON ABRASIVE CLEANER DO NOT IMMERSE IN WATER FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE AVERTISSEMENT Ne pas...

Страница 3: ...ABLE OF CONTENTS PRE INSTALLATION 1 FINAL INSTALLATION 1 OPERATION 1 2 PROGRAMMING 3 DEFAULT PRESET VALUES 4 DAILY MAINTENANCE 4 MONTHLY MAINTENANCE 5 TROUBLESHOOTING 6 8 REPLACEMENT PARTS 9 10 3BILLU...

Страница 4: ......

Страница 5: ...plenum is well latched in place and plugged in to the cabinet s See photos on page 7 3 Place cabinet in the stable base 4 Plug cabinet into 120v receptacle rated for 15 amps 5 Installation shall compl...

Страница 6: ...the cycle the LED bars will go back to steady and the beeping will stop 3 When the timer reaches the 000 value the display will flash 000 the LED bars will flash red and the beeping will start until t...

Страница 7: ...user programming mode and the display will alternate between the parameter display codes and the current value for that parameter Here is the list of the user programming parameters and functionaliti...

Страница 8: ...lean cabinet including shelves and base with a damp cloth rag and a mild cleaner DO NOT USE A GREEN SCOTCH BRITE PAD OR ANY OTHER ABRASIVE CLEANING PAD THE BLUE SCOTCH BRITE NO SCRATCH IS SAFE TO USE...

Страница 9: ...E A GREEN SCOTCH BRITE PAD OR ANY OTHER ABRASIVE CLEANING PAD THE BLUE SCOTCH BRITE NO SCRATCH IS SAFE TO USE DO NOT USE CAUSTIC CLEANING SOLUTIONS SUCH AS OVEN CLEANER USE ONLY A MILD NON ABRASIVE CL...

Страница 10: ...PTION BY THUNDERSTORM ETC B PRESS AND HOLD DOWN ARROW FOR 3 SECONDS TO CLEAR PHt CYCLE 2 UNIT WILL NOT TURN ON A UNIT UNPLUGGED A PLUG IN UNIT B IS CONTROLLER ON OFF SWITCH ON B TURN SWITCH ON C OUTLE...

Страница 11: ...URE SET POINT SEE PROGRAMMING SECTION B EXCESSIVE AIR DRAFT S B SHIELD DRAFT S 5 HIGH PRODUCT TEMPERATURE A TEMPERATURE SET POINTS ARE TO HIGH A ADJUST TO LOWER TEMPERATURE SET POINT SEE PROGRAMMING S...

Страница 12: ...P OR LO SHORTED TEMPERATURE SENSOR uP UPPER DECK OR LO LOWER DECK A TEMPERATURE WIRES ARE SHORTED A CHECK WIRES B BAD SENSOR B REPLACE SENSOR C BAD CONTROLLER C REPLACE CONTROLLER 10 TIMER COLOR LEDS...

Страница 13: ...if the controller is not operating according to specs or if it won t turn on when 8 5VDC is supplied to it 504345 Cord 14 3 SJTOW W STR 120V Plug 120V main power cord Damaged cord can cause unit to st...

Страница 14: ...f power delivered to their associated heater once it reaches temperature set point Failure will cause the associated heater to excessively rise above set point and might cause permanent damage to it 5...

Страница 15: ...Inc All rights reserved RV020216 169178FIG1 OVERALL DIMENSIONS DH5F 333ARB FIGURE 1 N S F T E S T I N G L A B O R A T O R Y A N N A R B O R M I C H 15 375 21 875 15 625 3 250 3 TWO CHANNELS CONTROLLER...

Страница 16: ...TH INSTRUCTIONS FOR THE SIMPLE PROGRAMMING NEEDED 162866 8 1 POWER SUPPLY 504318 9 6 RELAY SOLID STATE 25A 504023 10 6 PAN 1 3 AMBER 2 1 2 TALL 504331 11 2 BLANKET BOTTOM HEATER 504323 12 3 BLANKET TO...

Страница 17: ...UCT CLASS PRODUCT LINE GENERIC NAME All rights reserved REV CODE NTS DWG NO IMAGE MAY BE REDUCED SIZE SCALE A ROUTE DATE Copyright 2013 Marshall Air Systems Inc MARSHALL AIR SYSTEMS INC DRAWN BY MATER...

Отзывы: