OWNER’S MANUAL
MODEL DH5F-333ARB
– HEATED HOLDING CABINET
169178 RV020216
Copyright © 2016 Marshall Air Systems, Inc.
All Rights Reserved.
10
REPLACEMENT PARTS
– Feet, Rubber Black
Replace if damaged or missing.
Standard 1/3 size pan used to hold food
products
– Rear Cover
Replace if damaged or missing.
The 120VAC to 8.5VDC power supply is used to
power the time/temperature controllers. A
defective
power
supply
could
cause
all
controllers to not turn on when powered.
SSRs are used to turn on and off power
delivered to their associated heater once it
reaches temperature set point. Failure will
cause the associated heater to excessively rise
above set point and might cause permanent
damage to it.
- Sensor, RTD, 48"
Used to read heater's temperature. If a RTD
sensor goes bad or is disconnected, its
associated controller will beep and the display
will flash either "oPn" or "SHt" to indicate failure
- Switch, Double Pole
One switch for each deck is used to allow energy
efficiency. A bad switch could cause the
associated controller to not turn on. Bad or
damaged
switches
should
be
replaced
immediately.
Part Replacement Time: 10 min
Part Replacement Time: 8 min
Part Replacement Time: 10 min
Part Replacement Time
Upper Platen: 21 min
Lower Platen: 27 min
Part Replacement Time: 1 min
Содержание DH5F-333ARB