Explanation of Graphic Symbols 

 

SN-21300100 

Designation of the serial number of 

every device. 

(Number as an example) 

 

 

 

“Please note the accompanying 

documents” or “Observe operating 

instructions”

 

 

 

Charder Electronic Co. Ltd 

No.103 Guozhong Rd, Dali Dist, 

Taichung City 412, Taiwan (R.O.C)

 

Identification of manufacturer of 

medical product including address. 

 

 

 

Type B Applied Part. 

 

Dispose of old appliances separately 

from your household waste. 

This product must be disposed of at a 

communal collection point. 

 

Carefully read this operation manual 

before setup and commissioning, even if 

you are already familiar with Marsden 

scales. 

 

Transport and storage temperature limit 

indicating the upper and lower limit 

(transport and storage temperature on 

packaging). 

 

 

Page 5 

Содержание MHS-2500I

Страница 1: ...USER MANUAL MHS 2500I Please take time to read these instructions before starting to use the scale Version 1 0 05 17...

Страница 2: ......

Страница 3: ...of Graphic Symbols 5 Installing the Batteries 6 Before Using the Scale 7 Operation Basic Functions 8 Operation Advanced Functions 9 EMC Guidance and Manufacturer s Declaration 10 Recommended Separatio...

Страница 4: ...load capacity of 300kg which must not be exceeded Product Specification Model MHS 2500I Accuracy Class Class III Capacity Division 300kg x 100g Units of Measure Kg Function Keys ON ZERO TARE OFF HOLD...

Страница 5: ...uld be assisted in using the device Do not exceed the maximum capacity of the scale The safety requirements and notes on appropriate use from the hoist manufacturer must also be observed The device mu...

Страница 6: ...C Identification of manufacturer of medical product including address Type B Applied Part Dispose of old appliances separately from your household waste This product must be disposed of at a communal...

Страница 7: ...ation Please follow these instructions for installing the batteries 1 Locate the battery cover on the 2 Slide the battery cover off back of the scale 3 Remove the battery housing 4 Install 6x AAA size...

Страница 8: ...2500I is fitted to the hoist correctly and hangs straight A tilt of more than 3 during operation will cause the scale to display incorrect readings We do not recommend using the scale with a hoist ha...

Страница 9: ...le will show zero and a minus reading when the item is removed HOLD BMI During weighing press this button once to lock and hold the weight reading on the scale To disable the Hold function press once...

Страница 10: ...f time it will shut off automatically This function can be set to 120 sec 180 sec 240 sec 300 sec Press for three seconds to enter Setup mode will show on the display Press the ON OFF ZERO TARE button...

Страница 11: ...or the user of this scale should ensure that it is used in such an environment Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment Guidance Electrostatic discharge ESD IEC...

Страница 12: ...used in such an environment Immunity Test IEC 60601 test level Compliance level Electromagnetic environment guidance Conducted RF IEC 61000 4 6 3 Vrms 150 KHx to 80 MHz 3 Vrms Portable and mobile RF c...

Страница 13: ...iated RF disturbances are controlled The customer or the user of the scale can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications...

Страница 14: ...w zero range Check that nothing is on or catching the scale and retry Scale overload The scale s maximum capacity has been exceeded Please reduce the loading and try again Scale Underloaded The weight...

Страница 15: ...Manufacturer s Declaration of Conformity Page 14...

Страница 16: ...Page 15...

Страница 17: ...mail sales marsdengroup co uk Manufacturing and Distribution Unit 7 Centurion Business Park Coggin Mill Way Rotherham S60 1FB Head Office Unit 1 Genesis Business Park Sheffield Road Rotherham S60 1DX...

Отзывы: