2.3 

SETTING AND RECALL THE PRE-TARE FUNCTION 
 

 
 
 
 
 
 
 

Long  press 

TARE

  key  3sec  to  enter 

PRE-TARE setting mode. 

And then press 

TARE

 key again.   

(Over  3sec,  it  will  return  to  the  normal 

mode.) 

 
 
 
 
 
 
 

The  display  will  show  the  last  pre-tare 

entered  and  the  extreme  left  digit  will 

flash. 

Enter  the  pre-tare  value  by  using  the 

numeric  key  (e.g.  60.0kg),  then  press 

TARE

 key again to confirm the pre-tare 

value. 

 

 

Press ZERO key to return to the normal mode. 

 

Содержание M-610

Страница 1: ...M 610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES...

Страница 2: ...CHING ON 11 1 2 SWITCHING OFF 12 1 3 SETTING ZERO 12 2 0 ADVANCED FUNCTIONS 13 2 1 HOLD FUNCTION 13 2 2 BODY MASS INDEX BMI FUNCTION 14 2 3 SETTING AND RECALL THE PRE TARE FUNCTION 15 2 4 SETTING THE...

Страница 3: ...ll render the warranty null and void 4 Ensure the voltage marked on the power supply unit matches your mains power supply 5 This device is designed for use indoors 6 Observe the permissible ambient te...

Страница 4: ...16 You can obtain further details from your local council your municipal waste disposal company or the firm which you purchased the product 17 Explanation of the graphic symbols This EEC verification...

Страница 5: ...ppliances separately from your household waste l Instead take them to communal collection points Carefully read this operation manual before setup and commissioning even if you are already familiar wi...

Страница 6: ...displays low battery indication please plug in the AC adaptor for operation and rechargeable batteries where rechargeable batteries are installed for at least 4 5 hours if batteries are fully charged...

Страница 7: ...attery housing and reset the rechargeable battery 2 To make sure that the housing pin is connecting to the right point 3 Place the housing back and close the battery housing cover Rechargeable Battery...

Страница 8: ...T HOLD PRINT 0 9 Stabilisation Time 1 2 seconds Operating Temp and humidity 0 C 40 C 15 85 RH Transport and storage temp And humidity 20 C 60 C 10 95 RH Power supply 7 2V 2000mA Rechargeable battery p...

Страница 9: ...nter into the TIME setting mode ZERO The scale is reset to 0 0kg display It is possible to set max up to 2 of maximal load for verified scales and 2 or 100 of maximal load for common scales possibilit...

Страница 10: ...DESCRIPTION Definitions Stable symbol To indicate that the weight is stable Minor weight Weight under zero Zero symbols Weight is at zero point Power Index When the indicator show LO means Battery nee...

Страница 11: ...scale should be checked by competent personnel The weight indicator contains an internal rechargeable battery pack this should only be replaced by authorized service agents Under normal operating cond...

Страница 12: ...1 SWITCHING ON THE SCALE Press the ON OFF button firmly The scale will first test all of the display segments The scale will now show its current software version number The scale will now go into we...

Страница 13: ...ton when the scale is turned on The scale will power down 1 3 SETTING THE SCALE TO ZERO If for some reason the scale shows a reading other than 0 0kg then it can be reset to zero 2 of capacity Press t...

Страница 14: ...the HOLD button once The person should now get on to the scales After a few seconds the scale will lock on the person s weight When the person stand off the scale the weight will unlock automatic Pre...

Страница 15: ...cable automatically There will always be an active flashing digit in the height display unless the HOLD key is pressed Proceed to weigh as normal The instrument will show the weight height and BMI val...

Страница 16: ...ress TARE key again Over 3sec it will return to the normal mode The display will show the last pre tare entered and the extreme left digit will flash Enter the pre tare value by using the numeric key...

Страница 17: ...d The time period to be edited is selected by pressing the HOLD key E g To input 25 December 2008 8 00 a m Enter the year Press HOLD to confirm and access the date editing field Enter the date E g 12...

Страница 18: ...fitted the patient s weight height and BMI result can be printed on to a paper roll Once the person has been weighed and their BMI calculated simply press the print key to produce the following ticke...

Страница 19: ...MBLING TP2100 THERMAL PRINTER Plug the cable to the printer and then connect its 9D connector to the indicator 2 7 BLUETOOTH VERSION For Bluetooth version Bluetooth symbol will show on the panel Examp...

Страница 20: ...ng Note Disable the Bluetooth function will be helpful to save the power consumption when the Bluetooth is useless Display the bluEt menu Press TARE key once Press HOLD key return to normal mode Using...

Страница 21: ......

Страница 22: ...used by a serious fault on the scales such as a faulty load cell or wiring Please contact the local Service Representative Zero count over calibration Zero range 10 while powered on Please re calibrat...

Страница 23: ...being worked on at higher temperatures required by lead free soldering The restricted substances and maximum allowed concentrations in the homogenous material are by weight Substance Concentration Le...

Страница 24: ...OFFICE SALES SERVICE MARKETING AND ACCOUNTS UNIT 1 GENESIS BUSINESS PARK SHEFFIELD ROAD ROTHERHAM S60 1DX TELEPHONE 0845 130 7330 FAX 0845 1307440 DESPATCH AND PRODUCTION Unit 7 CENTURION BUSINESS PAR...