PH10 Unheated Series 

Phantom 10 Series 

Commercial Air Curtain 

Submittal Package 

 
 
 
 
 

 
 
 
 
 

 
 
 

Submitted by: 

Mars Air Systems, LLC 

14716 S. Broadway 

Gardena, CA 90248 

 
 
 
 

P.O.# 

 

 

 

S.Q. 

 

 

 

Company 

 

 

 

Print Name 

 

 

 

Signature  

 

 

Date 

 

 

Company Seal or Stamp

(Electronic Signature Preferred)

 

Содержание PH10 Unheated Series

Страница 1: ...ithout notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA PH10 Unheat...

Страница 2: ...notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Table of Contents...

Страница 3: ......

Страница 4: ...lumns to complete the model numbers AMCA Certified Lab Data Model Distance from nozzel in Avg Core Velocity FPM 40 1089 80 1000 120 900 160 822 Projection Velocity PH1036 1U Unheated Data Sheet Applic...

Страница 5: ......

Страница 6: ...oor type door limit switch installation FIG 1 2 Use light gauge materials when field fabricating brackets to activate and deactivate the door limit switch s FIG 2 Figure 2 also shows the typical insta...

Страница 7: ...nded Wall Mounting For Tandem Mounting of air curtain over sectional style door use either wall mounting angle brackets or threaded rods 4 Top Mounting Brackets For overhead installation of units use...

Страница 8: ...ies are 1 2 HP and 1 HP respectively The Phantom Series come standard with an air intake screen s GENERAL SAFETY INFORMATION Use this product only in the manner intended by the manufacturer If you hav...

Страница 9: ...e screen can be removed from the unit by pulling the spring loaded piano hinges FIG 1 3 All Phantom series have the Motor Fan Assembly MFA shipped internally mounted 4 All units are equipped with 4 3...

Страница 10: ...connected in accordance to National Electrical Code and wired per the enclosed wiring diagram For electric heated models ensure that the coils are secured and not touching each other on any metal surf...

Страница 11: ...he outdoor elements Contact factory for special construction and costing Freezer and Cooler Installation Air curtain must be mounted on the warm side for optimal performance Variable Frequency Drive V...

Страница 12: ...in this manual Obstruction on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating be...

Страница 13: ...esponsible for transportation charges associated with replacement of failed part Mars does not warrant uninterrupted or error free operation of Mars product Under no circumstance is Mars liable for an...

Страница 14: ...g Metal Studs D Section 07900 Joint Sealers E Section 08110 Steel Doors and Frames F Section 08330 Overhead Coiling Doors G Section 15145 Plumbing Piping Gas piping to units H Section 15182 Hydronic P...

Страница 15: ...1 Standard for Fixed and Location Dedicated Electric Room Heaters Intertek Testing Services Listed for US and Canada I CSA 3812 01 Fans and Blowers Certified to US Standards Canadian Standard Associat...

Страница 16: ...tions trouble shooting guide parts list and electrical wiring diagrams 1 5 QUALITY ASSURANCE A Manufacturer Qualifications Minimum ten years documented experience producing the products specified in t...

Страница 17: ...2 AIR CURTAIN ASSEMBLIES A Motor Fan Assembly Design for easy removal assembly repair and maintenance 1 Motor Totally enclosed air over TEAO cooled motor with sealed lifetime pre lubricated ball bear...

Страница 18: ...ghts to 10 feet 3048 mm 1 Discharge Nozzle Wedge shaped discharge outlet nozzle with adjustable air foil vanes with a plus minus 40 degree sweep front to back 2 Air Velocity at Nozzle a PH10 36 1 36 I...

Страница 19: ...ized steel bolted to air curtain housing 8 Supply and return fittings on ends of casing 9 Thermostat Wall mounted 110 Volt operation with heater on off selection C Hot Water Heaters Provide finned tub...

Страница 20: ...trol panel Provide a separate control panel for three phase motors controlled by a limit switch 1 Type Combination plunger roller switch for swing and sliding doors a Provide limit switches with NEMA...

Страница 21: ...st air curtains to function properly B Adjust air foil vanes located within the discharge nozzle as required for prevailing conditions at each opening C Check heated air curtain performance on a calm...

Страница 22: ...ing changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Reference Links Link Description http marsair com Main website http marsair co...