Memory Input
Your Automatic Digital Blood Pressure Monitor has a
memory feature. When a valid measurement is made,
the reading data (systolic, diastolic and pulse rate) will
be stored in the memory automatically as soon as the
unit is turned off, automatically shuts off, or when
another measurement is initiated.
The unit has the capacity to store 7 readings, and
also computes an average of up to the 7 memory
readings.
When more than 7 readings are taken and
recorded to memory, the oldest ones will be deleted.
Memory Recall
By pressing the
MEMORY
button, you will see "A" in the
lower left hand corner of the display. It means you are
looking at the average of all the measurement results.
Pressing the
MEMORY
button again, the newest set of
measurement results is indicated by "1". Press it
again, the next set will be displayed.
Memory Erase
When the batteries are taken out of the monitor, all re-
cords will be erased.
Note :
When taking a measurement, the
MEMORY
button
is inactive.
Memory Number
Error indicator
Indication: Cuff pressure reaches 330
mmHg.
Cause: Twisted bladder inside of the
cuff.
Correction: Make sure that the bladder
lays flat within the cuff.
Indication: Display "Err", cuff pressure
releases and "0" pressure
display.
Cause: Excessive arm movement or
talking during measurement.
Correction: Turn off and on the unit and
measure again while keeping
still.
Indication: Could not obtain pulse rate.
Cause: Cuff was loosely applied,
extremely weak pulse or
arrhythmia.
Correction: Reapply cuff and measure
again.
Batteries are exhausted.
MS-701K: Replace with four new "AA" batteries.
MS-702: Replace with four new "AAA" batteries.
Possible sources of errors
Error Indicators
Make sure that the batteries are installed
in the proper direction. (Polarity matches
to the indications in the battery case.)
Check that the cuff is positioned properly.
Go over the measurement procedure
again.
Check if the wrist is positioned properly.
Rest your arm on a table so that the cuff
is level with your heart during
measurement.
Remain seated during the entire
measurement period.
Refrain from hand and body movements
during measurement.
Your blood pressure can fluctuate
considerably through out the day. All of
the following factors can influence your
blood pressure:
¡@ Emotional state
¡@ Daily activities or exercise
¡@ Smoking
¡@ Drinking alcoholic beverages
¡@ Eating
¡@ Taking certain medications
Nothing
appears in
display
No
measurement
occurs
Blood
pressure
readings are
too high or
low
Blood
pressure
readings are
variable
Troubleshooting
Recommended Action
Problem