Mars Comfort-Aire RXTS Series Скачать руководство пользователя страница 31

IOM  -  

RXTS Series

31

 Page 31

Air Conditioner 

Features

FAN 

button

Press Fan button to select the Fan Speed in four steps-Auto, Low, Med or High. Each time the button 
is pressed, the fan speed mode is shifted.  For some models, the fan speed can not be adjusted.

7

ECO 

button

Press ECO button to initiate this function.  This function is available on COOL, DRY, and AUTO (only 
AUTO-COOLING and AUTO-FAN) modes. The fan will continue to run for 3 minutes after the compressor 
shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is 

above the set temperature, at which time the compressor turns back on and Cooling Starts. 

4

MODE 

button

To choose operating mode, press the MODE button. Each time you press the button, a mode is 
selected in a sequence that goes from Auto,  Cool,  Dry and Fan.  The indicator light beside the 
button will be illuminated and will remain on once that mode is selected.
The unit will automatically initiate the Energy Saver function under Cool,  Dry,  and Auto (only Auto-
Cooling and Auto-Fan) modes.
1. To operate on Auto feature :

•   When you set the air conditioner to Auto mode, it will automatically select cooling or fan only 

    operation,  depending on what temperature you have selected and the current room temperature.

•   The air conditioner will control the room temperature automatically based on the temperature 

    you set.

•   In this mode, the fan speed cannot be adjusted, it starts automatically at a speed according to the 

    room temperature.
2. To operate on COOL mode :

•   Choose Cool Mode to set the cooling function. Use the Up and Down buttons to choose the 

    desired temperature. When Cool Mode is selected,  the fan speed can be adjusted by pressing the 
    fan button.
3. To operate on Dry mode :

•   In this mode, the air conditioner will generally operate as a dehumidifier. Since the conditioned 

    space is a closed or sealed area, some degree of cooling will continue.  On Dry mode, the fan speed 
    is not adjustable.
4. To operate on Fan Only :

•   Use this function only when cooling is not desired, such as for room air circulation or to exhaust 

    stale air(on some models). (Remember to open the vent during this function, but keep it closed 

    during cooling for maximum cooling efficiency.)  You can choose any fan speed you prefer.
•  In Fan only mode, the temperature is not adjusted.

5

6

             

button

Press           or           button to change temperature setting.
NOTE: Press or hold either           or         button until the desired temperature is shown on the display. 

This temperature will be automatically maintained anywhere between 60

(16

) and 86

(30

). 

If you want the display to read the actual room temperature, see “To Operate on Fan Only” section.”

•  The selected time will register in 5 seconds,  and the system will automatically revert back to 

   display the previous temperature setting or room temperature when the unit is on.  When the unit 
   is off,  there is no display.

•  Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto 

   Start/Stop timed program.

Содержание Comfort-Aire RXTS Series

Страница 1: ...IOM RXTS Series 1 www comfort aire com Installation and Operation Manual RXTS Series U Rack Window Type Room Air Conditioner RXTS 81A RXTS 101A RXTS 121A...

Страница 2: ...RXTS Series 2 Table of Contents Important Safety Instructions 03 Installation Instructions 14 Normal Sounds Sound Performance 28 Air Conditioner Features 29 Care and Cleaning 33 Troubleshooting Tips...

Страница 3: ...e possibility of injury or damage to property Indicates information considered important but not hazard related WARNING DANGER Plug in power plug properly Do not modify power cord length Always ensure...

Страница 4: ...the power cord near flammable gas or combustibles such as gasoline benzene thinner etc Keep firearms away WARNING When the air filter is to be removed do not touch the metal parts of the unit It may...

Страница 5: ...not drink water drained from air conditioner Do not place obstacles around air inlets or inside of air outlet Use caution when unpacking and installing Sharp edges could cause injury CAUTION If water...

Страница 6: ...s Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have...

Страница 7: ...pecified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which...

Страница 8: ...gnition of the flammable refrigerant used Please follow the instructions carefully to store or maintain the air conditioner to prevent mechanical damage from occurring Flammable refrigerant R32 is use...

Страница 9: ...Work in confined spaces shall be avoided The area around the workspace shall be sectioned off Ensure that the conditions within the area have been made safe by control of flammable material 4 Checkin...

Страница 10: ...g corroded or are suitably protected against being so corroded 9 Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspecti...

Страница 11: ...shall not be used 11 Leak detection methods The following leak detection methods are deemed acceptable for systems containing flammable refrigerants Electronic leak detectors shall be used to detect...

Страница 12: ...e taken not to overfill the refrigeration system Prior to recharging the system it shall be pressure tested with OFN The system shall be leak tested on completion of charging but prior to commissionin...

Страница 13: ...ief valve and associated shut off valves in good working order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working orde...

Страница 14: ...IOM RXTS Series 14 Installation Instructions NOTICE The unit you purchased may look like one of the followings Page 14 Installation Instructions Model A Model B...

Страница 15: ...IOM RXTS Series 15 Page 15 Installation Instructions NOTICE All the illustrations in this manual are for explanation purpose only The actual installation may vary Model C Model D...

Страница 16: ...se IMPORTANT Observe all governing codes and ordianaces Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill leve...

Страница 17: ...pe B Screw 2 2 Window Sash Lock Window Sash Foam Window Sealing Foam Bracket Sealing Foam Additional Side Arm Foam 1 Type A Screw 2 2 1 1 1 1 Angled Support Arms Horizontal Bracket Spring Push Pin Mai...

Страница 18: ...in adjust the Left Extension Arm out and then install the Right Extension Arm Measure the width of the inner windowsill on your window Making sure that the center of the bracket will line up with the...

Страница 19: ...wsill by drilling 1 8 pilot holes and installing the 1 2 and 1 Type A screws as shown in Fig 7 B Move the Angled Support Arms toward the exterior wall until the feet touch the wall Place the level on...

Страница 20: ...level again and ensure the bracket feels secure After making any necessary adjustments insert the cotter pins into the Main Support Pins Cotter Pin E If necessary cover the holes on the front of the b...

Страница 21: ...n top of the support bracket Ensure the grooves on the bottom of the air conditioner align with the Main Supports Using a level check for proper tilt towards the outside WARNING Do not leave the unit...

Страница 22: ...screws as shown Use the 1 2 Type B screw Use the 1 4 Type B screw Fig 16 A Measure the distance between the Side Arm Hinge and the closest part of the window frame in line with the Side Arm Add 1 4 t...

Страница 23: ...conditioner Air Conditioner Side Vinyl Type Windows with Lipped Sill Window Sealing Foam Fig 18 Additional Side Arm Foam Wooden Type Windows with Flat Sill Window Sealing Foam Fig 19 Fig 20 C Insert S...

Страница 24: ...iew Extend into Window Track The factory installed 1 2 screw must be re used to secure the Anti Tip Bracket Failing to use this screw could damage the air conditioner Top of Unit D The Anti Tip Bracke...

Страница 25: ...Extend the Integrated Window Locks located in the U channel until they contact the window For additional security you can install the optional Sash Lock as shown Fig 25 Fig 26 FOAM SEAL Fig 24 G To s...

Страница 26: ...drain holes or slots are not caulked or painted shut Accum ulated rain water or condensation must be allowed to drain out You must secure the support bracket to the added wood piece using the provided...

Страница 27: ...its bottom portion 75 150cm above the floor level 6 The power cord must be connected to an independent circuit The yellow green wire must be grounded Installations of the unit into the wall OPTION A...

Страница 28: ...In front of the unit you may hear the sound of rushing air being moved by the fan High Pitched Chatter Vibration Unit may vibrate and Trickling Sound Gurgle Hiss noises may be heard NOTICE All the il...

Страница 29: ...w see Air Directional Louvers 6 Once the room has cooled adjust the thermostat to the setting you find most comfortable 7 Make sure the air flow inside and outside is not obstructed by anything Coolin...

Страница 30: ...he timer settings Press or hold the UP or DOWN button to change the Auto time by 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remain...

Страница 31: ...e fan speed cannot be adjusted it starts automatically at a speed according to the room temperature 2 To operate on COOL mode Choose Cool Mode to set the cooling function Use the Up and Down buttons t...

Страница 32: ...n automatic 3 minutes time delayed start if the unit is turned off and on quickly This prevents overheating of the compressor and possible circuit breaker tripping The fan will continue to run during...

Страница 33: ...r from the filter Be sure the filter is thoroughly dry before replacing Instead of washing you may vacuum the filter clean Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fi...

Страница 34: ...filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a higher sett...

Страница 35: ...ty of moisture from humid room This is normal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 f...

Страница 36: ...__________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _...

Страница 37: ...__________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _...

Страница 38: ...__________________________ _____________________________________________________________________________________ _____________________________________________________________________________________ _...

Страница 39: ...emedy under the Limited Warranty is replacement of the defective unit Labor to diagnose and replace the defective unit is not covered by this Limited Express Warranty If for any reason the replacement...

Страница 40: ...HQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW...

Отзывы: