Safety 

Precautions

 Page 5

 WARNINGS FOR PRODUCT INSTALLATION

1.

 

Installation must be performed by an authorized dealer or specialist. Defective installation can 

cause water leakage, electrical shock, or fire. 

2.

 

Installation must be performed according to the installation instructions. Improper installation  

can cause water leakage, electrical shock, or fire. 

(

In North America,installation must be performed in accordance with the requirement of NEC  

and CEC by authorized personnel only.)

3.

 

Contact an authorized service technician for repair or maintenance of this unit. This appliance 
shall be installed in accordance with national wiring regulations.

4.

 

Only use the included accessories, parts, and specified parts for installation. Using non-standard 

parts can cause water leakage, electrical shock, fire, and can cause the unit to fail. 

5.

6.

 

Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot 

support the unit’s weight, or the installation is not done properly, the unit may drop and cause 

serious injury and damage.

7.

8.

9.
10.

11.

Do not turn on the power until all work has been completed.
When moving or relocating the air conditioner, consult experienced service technicians for 
disconnection and reinstallation of the unit.
How to install the appliance to its support, please read the information for details in "indoor unit 
installation" and "outdoor unit installation" sections .

   

For units that have an auxiliary electric heater, 

do not 

install the unit within 1 meter (3 feet) of   

any combustible materials. 

   

Do not

 install the unit in a location that may be exposed to combustible gas leaks. If  

combustible gas accumulates around the unit, it may cause fire.

   

Install drainage piping according to the instructions in this manual. Improper drainage may 

cause water damage to your home and property. 

   

Note about Fluorinated Gasses(Not applicable to the unit using R290 Refrigerant)

1.    

This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the 

type of gas and the amount, please refer to the relevant label on the unit itself or 

the

 “Owner's Manual - Product Fiche ” in the packaging of the outdoor unit. 

(European 

Union products only)

.  

2.

   

Installation, service, maintenance and repair of this unit must be performed by a certified 

technician. 

3.

 

Product uninstallation and recycling must be performed by a certified technician.

4.    

For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO

2

 

equivalent or more, but of less than 50 tonnes of CO

2

 equivalent, If the system has a leak-

detection system installed, it must be checked for leaks at least every 24 months. 

5.

   

When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.

4. 

 Before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol 

     for the conducting USER MAINTENANCE, it is recommended to disconnect the power. 
5.  The UV-C lamp can not be cleaned, repaired and replaced.   
6.  UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.

 WARNING

This appliance contains an UV emitter. Do not stare at the light source.

Содержание Comfort-Aire Century A-DVH09SH-0-CY

Страница 1: ...www marsdelivers com Owner s Manual Installation Manual DVH Series Inverter Single Zone Ductless Mini Split DVH09SH 0 DVH09SH 1 DVH12SH 0 DVH12SH 1 DVH18SH 1 DVH24SH 1...

Страница 2: ...Owner s Manual Table of Contents Safety Precautions 03 Care and Maintenance 12 Troubleshooting 14 1 Indoor unit display 07 2 Operating temperature 09 3 Other features 10 4 Setting angle of airflow 11...

Страница 3: ...t 25 Outdoor Unit Installation 26 1 Select installation location 26 2 Install drain joint 27 3 Anchor outdoor unit 27 4 Connect signal and power cables 29 Refrigerant Piping Connection 30 A Note on Pi...

Страница 4: ...ALL INVERTER MINI SPLITS REQUIRE 14 4 STRANDED WIRE BETWEEN THE INDOOR AND OUTDOOR UNITS NO EXCEPTIONS 14 AWG 4 C TRAY CABLE A14 4SRBTHHNBK 14 AWG 19 0147 BC 4 C THHN CONDUCTORS POWER CONTROL TRAY CAB...

Страница 5: ...not insert fingers rods or other objects into the air inlet or outlet This may cause injury since the fan may be rotating at high speeds Do not use flammable sprays such as hair spray lacquer or pain...

Страница 6: ...exceeding 30mA and disconnection must be incorporated in the fixed wiring in accordance with the wiring rules For all electrical work follow all local and national wiring standards regulations and th...

Страница 7: ...o not install the unit within 1 meter 3 feet of any combustible materials Do not install the unit in a location that may be exposed to combustible gas leaks If combustible gas accumulates around the u...

Страница 8: ...ot be mixed with general household waste WARNING for Using R32 R290 Refrigerant 2 2 2 2 2 When flammable refrigerant are employed appliance shall be stored in a well ventilated area where the room siz...

Страница 9: ...OFF remains on when TIMER ON is set FRESH UV C lamp SWING TURBO SILENCE or SOLAR PV ECO feature is turned on for 3 seconds when TIMER OFF is set FRESH UV C lamp SWING TURBO SILENCE or SOLAR PV ECO fea...

Страница 10: ...OFF is set FRESH UV C lamp SWING TURBO or SILENCE features is turned off when defrosting for cooling heating units when unit is self cleaning some units when fresh feature is turned on some units whe...

Страница 11: ...2 F 15 C 30 C 5 F 86 F 0 C 50 C 32 F 122 F 0 C 52 C 32 F 126 F For special tropical models 0 C 52 C 32 F 126 F For special tropical models 15 C 50 C 5 F 122 F For models with low temp cooling systems...

Страница 12: ...settings to stay comfortable This function can only be activated via remote control And the Sleep function is not available in FAN or DRY mode Press the SLEEP button when you are ready to go to sleep...

Страница 13: ...do not use this function unless the remote control is lost and it is absolutely necessary To restore regular operation use the remote control to activate the unit Unit must be turned off before manua...

Страница 14: ...be bad for your health Make sure to clean the filter once every two weeks 1 Lift the front panel of the indoor unit 2 Grip the tab on the end of the filter lift it up then pull it towards yourself 3...

Страница 15: ...If you plan not to use your air conditioner for an extended period of time do the following Clean all filters Turn on FAN function until unit dries out completely Turn off the unit and disconnect the...

Страница 16: ...Troubleshooting Troubleshooting The unit changes from COOL HEAT mode to FAN mode The indoor unit makes noises A rushing air sound may occur when the louver resets its position A squeaking sound may o...

Страница 17: ...customer service center Provide them with a detailed description of the unit malfunction as well as your model number Troubleshooting Troubleshooting When troubles occur please check the following po...

Страница 18: ...oor heating performance The outdoor temperature is extremely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors and windows are closed during use...

Страница 19: ...Shape Quantity PC Need to be installed on the back of main air filter by the authorized technician while installing the machine Mounting plate fixing screw Remote controller Fixing screw for remote co...

Страница 20: ...Wall Hole 4 9 90 0 5 55 5i in n 2 2 3 3m m 4 4 7 75 5i in n 1 12 2c cm m Mount Indoor Unit STEP 8 Wrap Piping and Cable not applicable for some locations in North America Connect Piping Prepare Drain...

Страница 21: ...requirement of local and national standards The installation may be slightly different in different areas Wall Mounting Plate Power Cable Some Units Refrigerant Piping Signal Cable Remote Controller...

Страница 22: ...refrigerant piping While choosing a location be aware that you should leave ample room for a wall hole see Drill wall hole for connective piping step for the signal cable and refrigerant piping that c...

Страница 23: ...ke sure to avoid wires plumbing and other sensitive components Type A Type B 101mm 4in 179mm 7 05in 136mm 5 35in 37mm 1 45in 290mm 11 4in 49mm 1 95in Right rear wall hole 65mm 2 5in Indoor unit outlin...

Страница 24: ...side Right hand side Left rear Right rear Knock out Panel CAUTION Be extremely careful not to dent or damage the piping while bending them away from the unit Any dents in the piping will affect the u...

Страница 25: ...the compressor or any moving parts within the unit If the unit has an auxiliary electric heater it must be installed at least 1 meter 40in away from any combustible materials To avoid getting an elect...

Страница 26: ...on the back DRAIN HOSE MUST BE ON BOTTOM Make sure that the drain hose is at the bottom of the bundle Putting the drain hose at the top of the bundle can cause the drain pan to overflow which can lea...

Страница 27: ...pressure to the left and right hand sides of the unit The unit should not jiggle or shift 6 Using even pressure push down on the bottom half of the unit Keep pushing down until the unit snaps onto th...

Страница 28: ...that air outlet fan is at a 90 angle to the direction of the wind If needed build a barrier in front of the unit to protect it from extremely heavy winds See Figures below Strong wind Strong wind Stro...

Страница 29: ...bber seal see Fig B do the following 1 Insert the drain joint into the hole in the base pan of the unit The drain joint will click in place 2 Connect a drain hose extension not included to the drain j...

Страница 30: ...Remove the nuts from expansion bolts and place outdoor unit on bolts 6 Put washer on each expansion bolt then replace the nuts 7 Using a wrench tighten each nut until snug WARNING WHEN DRILLING INTO C...

Страница 31: ...amp down tightly 1 Remove the wire cover from the unit by loosening the 3 screws 2 Dismount caps on the conduit panel 3 Temperarily mount the conduit tubes not included on the conduit panel 4 Properly...

Страница 32: ...et substances or gases other than the specified refrigerant enter the unit The presence of other gases or substances will lower the unit s capacity and can cause abnormally high pressure in the refrig...

Страница 33: ...alling into the pipe 2 Using a reamer or deburring tool remove all burrs from the cut section of the pipe Pipe Reamer Point down Step 3 Flare pipe ends Proper flaring is essential to achieve an airtig...

Страница 34: ...0 76 0 78 23 2 23 7 0 91 0 93 18 20 180 200kgf cm 32 39 320 390kgf cm 49 59 490 590kgf cm 57 71 570 710kgf cm 67 101 670 1010kgf cm 9 52 0 375 12 7 0 5 16 0 63 19 0 75 1 Unscrew the cover from the pa...

Страница 35: ...for at least 15 minutes or until the Compound Meter reads 76cmHG 10 Pa 2 3 4 5 5 6 Close the Low Pressure side of the manifold gauge and turn off the vacuum pump 7 Wait for 5 minutes then check that...

Страница 36: ...0Btu h and 24000Btu h ADDITIONAL REFRIGERANT PER PIPE LENGTH Connective Pipe Length m Air Purging Method Additional Refrigerant Standard pipe length Vacuum Pump N A Standard pipe length Vacuum Pump Li...

Страница 37: ...Water Method Using a soft brush apply soapy water or liquid detergent to all pipe connection points on the indoor unit and outdoor unit The presence of bubbles indicates a leak Leak Detector Method If...

Страница 38: ...re of the refrigerant circuit will increase This may reveal leaks that were not present during your initial leak check Take time during the Test Run to double check that all refrigerant pipe connectio...

Страница 39: ...ging bag Outdoor Unit 1 Cut the packing belt 2 Take the unit out of the carton 3 Remove the foam from the unit 4 Remove the packaging bag from the unit Packing Indoor unit 1 Put the indoor unit into t...

Страница 40: ...r The consumer must retain a receipted bill of sale as proof of warranty period Without this proof the express warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED E...

Страница 41: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 42: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 43: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...

Страница 44: ...GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEO...

Отзывы: