INDOOR UNIT PARTS AND MAJOR FUNCTIONS
Air outlet
Air inlet
Unit Parts
Operating Conditions
Use the system under the following temperatures for safe and
effective operation. If the air conditioner is used under different
conditions, it may malfunction or become less efficient.
COOL mode
HEAT mode
DRY mode
Room Temperature
16°C - 32°C
(60°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C
(32°F - 122°F)
-15°C - 24°C
(5°F - 75°F)
0°C - 50°C
(32°F - 122°F)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
0°C - 52°C
(32°F - 126°F)
(For special
tropical models)
-15°C - 50°C
(5°F - 122°F)
(For models with
low temp. cooling
systems.)
FOR OUTDOOR UNITS WITH AUXILIARY ELECTRIC HEATER
When outside temperature is below 0°C(32°F ), we strongly
recommend keeping the outdoor unit powered at all times to
prevent damage to equipment.
NOTICE
Room relative humidity less than 80%. If the air conditioner operates in excess of this figure,
the surface of the air conditioner may attract condensation.
Indoor Unit
Parts And
Major Functions
Room
Temperature
16°C-32°C (60°F-90°F)
0°C-30°C
(32°F-86°F)
10°C-32°C (50°F-90°F)
Outdoor
Temperature
18°C-43°C (64°F-109°F)
-7°C-24°C
(19°F-75°F)
11°C-43°C (52°F-109°F)
-7°C-43°C (19°F-109°F)
(For models with low-temp cooling systems)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F-126°F)
(For special tropical models)
18°C-52°C (64°F-126°F)
(For special tropical models)
COOL mode
HEAT mode
DRY mode
Fixed-speed Type
Inverter Split Type