MARS Company MK-I/II Скачать руководство пользователя страница 24

 

 

 

Information to the User 

 

Warning: 

Changes or modifications to this device not expressly approved by 

MARS Company could void the user’s authority to operate the equipment. 

FCC Class B: 

“NOTE: This equipment has been tested and found to comply with the limits for a 

Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in a 

residential installation. This equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of the following 

measures: 

•  Reorient or relocate the receiving antenna. 

•  Increase the separation between the equipment and receiver. 

•  Connect the equipment into an outlet on a circuit different from that to 

which the receiver is connected. 

•  Consult the dealer or an experienced radio/TV technician for help.” 

 

RF Exposure: 

This equipment complies with FCC radiation exposure limits set forth for an 

uncontrolled environment. This equipment should be installed and operated with 

minimum distance 20cm between the radiator and your body. This transmitter 

must not be co-located or operating in conjunction with any other antenna or 

transmitter. 

Innovation, Science, and Economic Development (ISED) Canada: 

This device complies with Industry Canada license-exempt RSS standard(s).  Operation is subject to 

the following two conditions: (1) this device may not cause interference, and (2) this device must 

accept any interference, including interference that may cause undesired operation of the device. 

 

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio 

exempts de licence.  L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit 

pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage 

radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. 

 

Cet équipement est conforme aux limites d’exposition aux radiations dans un environnement non 

contrôlé.  Cet équipement doit être installé et utilize à distance minimum de 20 cm entre le 

radiateur et votre corps.  Cet émetteur ne doit pas être co-localisées ou opérant en conjonction avec 

tout autre antenne ou transmetteur. 

 

 

Page 21 of 21 

 

Содержание MK-I/II

Страница 1: ...8 USA Voice 770 831 8048 Fax 770 831 8598 Certification Exhibit FCC ID SJS 400099WH IC 5379A 400099WH FCC Rule Part 15 247 IC Radio Standards Specification RSS 247 ACS Project Number 16 0481 Manufacturer MARS Company Model 400099WH Manual ...

Страница 2: ...MARS SmartTransmitter MK I II MARS SmartTransmitter VHP FlowBridge FlowCast Installation and Programming Guide ...

Страница 3: ...Revision 1 E CM January 2017 MARS Company A Division of OW Investors LLC 800 782 5268 sales marswater com ...

Страница 4: ...y Step Guide 8 MK I II Programming Configurations Parameters Explained 9 MK I II Programming Configurations Meter Type Settings 10 VHP Programming Configurations Step by Step Guide 12 VHP Programming Configurations Parameters Explained 14 VHP Programming Configurations Meter Type Settings 15 Troubleshooting 17 Contact Us 19 Information to the User FCC Information 21 Page 1 of 21 ...

Страница 5: ...Page 2 of 21 ...

Страница 6: ...There are various materials that may be needed for each task which are presented in the beginning of each section It is recommended that you have these nearby Notes are listed in italics next to or underneath the section they are referring to They will list suggestions or offer advice on the adjacent topic Sections in BOLD letters must be followed exactly otherwise device operation will be adverse...

Страница 7: ... attach each wire to its respective terminal as outlined in MARS SmartTransmitter FlowBridge FlowCast Wiring Configurations For a meter with a pre wired lead wire strippers will be needed to remove the outer jacket on the lead and Gel Caps are recommended by MARS to attach the SmartTransmitter FlowBridge FlowCast to the meter First remove the outer jacket on the pre wired lead When removing the ou...

Страница 8: ...Meter Green Elster AMCO Absolute Encoder InVISION Neptune ARB V Radio Green Meter Red Radio Green Meter Red Radio Red Meter Green Radio Red Meter Black Radio Black Meter Black Radio Black Meter Green AMCO ABB Kent Scancoder Elster AMCO Digital Register pulse Radio Green Meter Red Radio Green Meter Black Radio Red Meter Green Radio Red Meter Green Radio Black Meter Black Radio Black Meter Red Sever...

Страница 9: ...Pit Mount MK II VHP SmartTransmitter Wall Mount MK II VHP SmartTransmitter MK I SmartTransmitter Page 6 of 21 Inductive Coil Locations Center SmartReader nozzle on these points FlowBridge FlowCast MK IV ...

Страница 10: ...tReader is fully charged The center of the black nozzle on the SmartReader must be centered over the locations shown on the left when a function is being processed and the center of the black nozzle of the SmartReader MUST be flush with the SmartTransmitter FlowBridge FlowCast housing The SmartReader can NOT be moved or pulled away from the SmartTransmitter FlowBridge FlowCast until the function i...

Страница 11: ...all parameters at one time Proceed to Step 6 when all relevant parameters are set On the next page is an explanation of each parameter and the available choices 6 Once each parameter is programmed to your specification press the F6 key on the SmartReader and hold the nozzle of the SmartReader against the SmartTransmitter as outlined in this section s Overview Press the Enter key or pull the trigge...

Страница 12: ...F combines both the TIMED and MON FRI so the SmartTransmitter will only wake up start transmitting Monday through Friday between the Start Time and End Time and sleep stop transmitting at night and on the weekends This is the MARS recommended setting Start Time Wake up time for the Time Mode setting See above End Time Sleep time for the Time Mode setting See above Radio ID PULSE ARB V ONLY 10 digi...

Страница 13: ...ter Badger RTR Master Meter pulse Performance Meters pulse Severn Trent SM700P Elster AMCO PSMT As these are popular configuration choices there are many other configurations that are possible with the MARS SmartTransmitter FlowBridge FlowCast For further information or to check meter compatibility please see the Contact Us section in this manual Radio ID Pulse Factor Pulse Digits and Pulse Number...

Страница 14: ...me a register advance of 1 on wheel number 6 again in our example 0 0 0 0 0 1 0 0 How many pulses did it take us to get to this point a full revolution of the sweep hand This will be variable a in the MARS Pulse Factor Formula Using this formula and padding zeros in front of the pulse factor to keep 8 digits this is the pulse factor to use when configuring these radios This pulse factor which can ...

Страница 15: ...creen will be updated Press the Exit key twice g Press the up arrow key twice to select MARS RADIO SET UP and press the Enter key or pull the trigger Proceed to Step 5 4 Press the down arrow once to highlight MARS RADIO SET UP Press Enter key or pull the trigger 5 You now have the option to use either a user defined setting or a preset configuration If these configurations are preset proceed to St...

Страница 16: ...l the trigger or press the Enter key twice to reenter the Configuration This will allow you to use the Configuration and disallow further changes unless the password is entered as in Step 8 13 Use the arrow keys to highlight the configuration and press the Enter key or pull the trigger 14 Press the F4 key and follow any prompts When this function is complete the SmartTransmitter is programmed 15 P...

Страница 17: ...YS assume the ID of the register Serial No NOT USER CHANGEABLE Internal serial number Pulse Fact PULSE ARB V ONLY 8 Digit pulse multiplier for the internal odometer of the SmartTransmitter It is ALWAYS read left to right This tells the SmartTransmitter what each pulse means as far as advancing the internal odometer to match the meter Example Meter is configured for 1 pulse gallon The utility wants...

Страница 18: ...configured for Sensus output such as the Elster AMCO InVISION Absolute Encoder with the blue leak detector STMS Enc Severn Trent SmartMeter Example SM700E Other Puls Standard 2 or 3 wire pulse switches registers Performance Meters pulse Severn Trent SM700P As these are popular configuration choices there are many other configurations that are possible with the MARS SmartTransmitter FlowBridge Flow...

Страница 19: ...specially for registers that are not as straightforward as this assume a register advance of 1 on wheel number 6 again in our example 0 0 0 0 0 1 0 0 How many pulses did it take us to get to this point a full revolution of the sweep hand This will be variable a in the MARS Pulse Factor Formula Using this formula and padding zeros in front of the pulse factor to keep 8 digits this is the pulse fact...

Страница 20: ...s Radio Info scroll down past the bottom of the Main Menu screen to find Radio Tools X should be a number VERY close to 908750000 If it is not near this number go to the Main Menu Radio Tools Set Rx Frequency scroll down past the bottom of the screen for this option Press Enter Key in 908750000 on the number pad Press Enter The receiver frequency will be updated Make sure the nozzle is properly at...

Страница 21: ...Page 18 of 21 ...

Страница 22: ...in this book or if you have additional questions please find our information below MARS Company Ocala FL USA Toll Free 800 782 5268 Telephone 352 694 7195 Fax 352 694 7397 Web http www marswater com amr support request Email sales marswater com customerservice marswater com Page 19 of 21 ...

Страница 23: ...Page 20 of 21 ...

Страница 24: ...adio TV technician for help RF Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Innovation Science and Economic Development...

Отзывы: