ZEUS4-MC Lite
INSTALLATION MANUAL
44
19.11
IPMOD
This parameter is used to define connection mode. Device supports two possible modes of
connection. First mode is used to connect to the server only when is needed (when reporting events)
this is a preferred mode, because it limits the traffic load on the server side. Second mode is used
when “all the time” connection is needed, the device keeps the connection alive all the time (ZEUS
S-Lite-GPRS automatically reconnects in case of errors).
Possible values:
0 – Connection established when needed
1 – Permanent connection.
19.12
IPPR
This parameter is used so to select connection protocol for event reporting.
NOTE
Contact your sales office for detail information about different options!
19.13
IPCRE
This parameter is used to define number of resending attempts in case of sending errors. If value
defined is reached all current events, which were not send, are skipped.
Possible values:
0 – resending limit is disabled
>0 – resending limit is defined
NOTE
In case resending limit is disable this may cause countless connection attempts.
19.14
PIP
This is print command used to check the IP settings of the on device.
Example:
;PIP;
With special syntax the user can check the stage of IP connection. The status is returned it text form
describing the status of the GPRS-TCP/IP connection.
Example:
;PIP=?;