CHECKING THE INPUT STATUS
User can check input status with the use of SMS command
14.1
CHECKING INPUT STATUS BY SMS COMMAND
By sending this command to ZEUS4-MC LITE you receive SMS message with all Input status:
;INS;
Return SMS message is:
;INS(1-4)=(OPEN-ON) – alarm loop is open and the input is in alarm state
;INS(1-4)=(OPEN-OFF) – alarm loop is open and the alarm input is in idle state
;INS(1-4)=(LOW-ON) – alarm loop is close on GND and the input is in alarm state
;INS(1-4)=(LOW-OFF) – alarm loop is close on the GND and the alarm input is in idle state
;INS(1-4)=(HGH-ON) – alarm loop is close on +12MCC and the input is in alarm state
;INS(1-4)=(HIGH-OFF) – alarm loop is close on +12V and the alarm input is in idle state