ZEUS4-MC Lite
PSTN/GSM/GPRS INTERFACE &
SMS GSM ALARM COMMUNICATOR
INSTALLATION MANUAL
Version Rev.12+: ZEUS4-MC LITE_Manual_2_4 03082015.doc
Страница 1: ...ZEUS4 MC Lite PSTN GSM GPRS INTERFACE SMS GSM ALARM COMMUNICATOR INSTALLATION MANUAL Version Rev 12 ZEUS4 MC LITE_Manual_2_4 03082015 doc ...
Страница 2: ...E NUMBERS PTN 31 11 4 RECEIVE LINKS PLN 31 11 5 RECEIVE INPUT PARAMETERS PIN 31 11 6 RECEIVE INPUT FILTER VALUE PID 31 11 7 RECEIVE DELAY BEFORE DIAL VALUE PDD 32 11 8 RECEIVE INPUT FILTER PARAMETERS PIF 32 11 9 RECEIVE CREDIT CHECK NUMBERS PCN 32 11 10 RECEIVE CREDIT CHECK PARSE STRING PARAMATERS PCREF 32 11 11 RECEIVE CREDIT STATUS FOR CC1 PCC1 32 11 12 RECEIVE CREDIT STATUS FOR CC2 PCC2 32 11 1...
Страница 3: ... 37 14 1 CHECKING INPUT STATUS BY SMS COMMAND 37 15 CHECKING AND CHANGING OUTPUTS 38 15 1 CHECKING OUTPUT STATUS BY SMS COMMAND 38 15 2 OUTPUT REMOTE CONTROL BY SMS COMMAND 38 16 CHANGING PARAMETERS USING THE SMS COMMAND 39 17 CONFIGURATION EXAMPLES 40 17 1 ALARM CONFIGURATION 40 17 2 CID EVENT REPORTING 40 18 GPRS TCP IP CONNECTION BASICS 41 19 GPRS TCP IP CONFIGURATION 42 19 1 IPEN 42 19 2 IPCID...
Страница 4: ...OD parameters example 17 Table 19 IT AR and IB parameters 17 Table 20 IT AR and IB parameters example 18 Table 21 Alarm SMS formatting 18 Table 22 ZEUS4 MC LITE DTMF commands 19 Table 23 Credit checking parameters 20 Table 24 Credit checking parameters example 20 Table 25 Set up parameters 24 Table 26 Set up parameters example 25 Table 27 CID parameters 26 Table 28 CID parameters example 27 Table ...
Страница 5: ...tible to interference which could affect performance SWITCH OFF IN HOSPITALS Follow any restrictions Switch the unit off near medical equipment SWITCH OFF IN AIRCRAFT Follow any restrictions Wireless devices can cause interference in aircraft SWITCH OFF WHEN REFUELING Do not use the unit at a refueling point Do not use near fuel or chemicals SWITCH OFF NEAR BLASTING Follow any restrictions Do not ...
Страница 6: ...ossible to set it up ZEUS4 MC LITE acts as normal PSTN telephone line when communicating with Central Monitoring Station through Contact ID protocol but it uses GSM network ZEUS4 MC LITE can be used in connection with different telephone equipment such as Alarm panels with built in digital communicator Automatic voice digital or signal telephone dialers Standard telephone sets PABX private telepho...
Страница 7: ...ting Download programming by SMS Up to 1000 event log buffer Prepaid cards credit and value checking Security protected for incoming calls Main and Battery power control Events can be transferred to the server installed in Central Monitoring Station via GPRS TCP IP connection Applications Backup for standard PSTN telephone line Standalone telecommunication unit instead of PSTN line Money save in o...
Страница 8: ... when you insert the SIM Connect the antenna to antenna connector Connect alarm inputs and outputs to ZEUS4 MC LITE Connect device to source power supply voltage Wait until LED3 display is turned ON green and LED1 blue starts flashing This is set in around 1 minute ZEUS4 MC LITE unit is now ready to operate IMPORTANT Before sending any SMS commands to ZEUS4 MC LITE device ZEUS4 MC LITE must be in ...
Страница 9: ...rminals La Lb Red LED LED2 alarm state During an alarm event the red LED indicates on which input alarm has been triggered For example if alarm was triggered on the first input there is 1 LED flash on second input 2 LED flashes etc Green LED LED3 When the alarm inputs on the unit are in active state SYS 1 then the green LED is ON With alarm inputs disabled the green LED goes OFF SYS 0 Yellow LED L...
Страница 10: ...ot new and it already has some data stored in the phone book memory By sending this SMS to ZEUS4 MC LITE all programmed parameters and numbers are cleared SDCLR After sending SMS you should wait at least 60 second for the command to be executed NOTE By sending this command to the ZEUS4 MC LITE all programmed data is erased from the SIM card including SMS messages ...
Страница 11: ...ZEUS4 MC Lite INSTALLATION MANUAL 7 7 CONNECTING DIAGRAM Figure 1 Connection diagram Micro SIM in newer versions ...
Страница 12: ... PSTN line is still active For the GSM priority function the IN parameter must be 4 5 or 6 Output 1 First diagnostic remote control or alarm output It is Open Collector output with maximum loading current of 500mA Output 2 Second diagnostic remote control or alarm output It is Open Collector output with maximum loading current of 500mA Ta Tb Terminal blocks for user to connect his equipment teleph...
Страница 13: ...pports different types of programming To program ZEUS4 MC LITE parameters put the SIM card into your personal GSM phone Add programming parameters in SIM Card Phone Book You can program ZEUS4 MC LITE remotely by SMS command You can program ZEUS4 MC LITE with USB key and SIM manager ...
Страница 14: ...ber is programmed the ZEUS4 MC LITE can accept ALL CALLS Remote SMS programming and remote controlling is possible from any phone Table of parameters Name value Comment SL 0 All calls and SMS are accepted SL 1 Only number stored under parameter TN1 has access to unit SL 2 Numbers stored under parameters TN1 to TN2 have access to unit SL 3 Numbers stored under parameters TN1 to TN3 have access to u...
Страница 15: ...or 6 IN 0 Normal Open triggered with negative voltage GND IN 1 Normal Close breaking negative or positive voltage loop IN 2 Normal Open triggered with positive voltage 12MCC IN 3 Input disable IN 4 IN 0 input reset SMS IN 5 IN 1 input reset SMS IN 6 IN 2 input reset SMS INPUT 1 2 N O Contact GND INPUT 1 2 N O Contact 12V DC INPUT 1 2 N C Contact INPUT 1 2 N O Contact 12V DC Figure 2 Output configu...
Страница 16: ... Name Number Description ID1 5 ID filter is 5 seconds for input 1 ID2 30 ID filter is 30 seconds for input 2 Table 6 ID parameters example Remote programming by SMS ID1 5 ID2 30 10 2 3 DD parameters If you would like to have a delay before unit starts dialing procedure use DD delay before dialing parameter Table of parameters Name Comment DD1 Delay before dialing for Input 1 DD2 Delay before diali...
Страница 17: ...number Table 9 TN parameters NOTE By pressing on your phone you switch OFF the redial call for calling number The remaining numbers are called as usual By pressing you switch off all remaining calls Example When you need to send an alarm beep message and SMS message to the first telephone number and only alarm beep message to the second one and only SMS message to the third one See the table below...
Страница 18: ...rameters Example Direct programming on the SIM card ZEUS4 MC LITE PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description LN8 12 Refill SIM SMS is sent to TN1 TN2 LN1 13 Input1 is called sent SMS to TN1 TN3 LN2 123 Input2 is called sent SMS to TN1 TN2 TN3 LN7 12 Periodic Test SMS is sent to TN1 TN2 Table 12 LN parameters example Remote programming by SMS LN8 12 LN1 13 LN2 123 LN7 12 10 2 6 M...
Страница 19: ...rol after which the ZEUS4 MC LITE will send Battery power level notifications Time can be set between 1 and 9999 seconds Table of parameters Name Comment MAIN Main Power Lost filter BATT Battery Power Lost filter Table 13 MAIN BATT parameters Example Direct programming on the SIM card ZEUS4 MC LITE PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description MAIN 5 Main power must be down 5s to s...
Страница 20: ...r Description OS1 1 Bistable toggle mode OS2 14 Monostable pulse mode 14s pusle Table 16 OS parameters example Remote programming by SMS OS1 1 OS2 14 10 2 8 OD parameters OD parameters are used to link alarm events directly to output OD1 and OD2 are used to link input events to output other are used for internal function notification Table of parameters Name Comment OD1 Input 1 direct link to outp...
Страница 21: ...ch maximum AR number of alarm can be triggered AR parameter defines the maximum number of alarms trigged in IT time IB IB parameter defines how long in seconds sending of alarm events is blocked when automatic input block system in enabled Table of parameters Name Comment IT1 Time interval 1st input IT2 Time interval 2nd input AR1 Maximum allowed number of events on 1st input AR2 Maximum allowed n...
Страница 22: ...ssage is built from 3 parts and user can write the first User Location and the second alarm event part of the message Unit adds the third part alarm event description automatically Language of the 3rd part may be changed by LNG parameter The message is stored in the SIM phone book so you should add any number for correct operation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 U S E R L O C A T I O N 1 ...
Страница 23: ...efined by LCV parameter or SIM card validity is near to expiration NOTE For support of different GSM providers contact support 10 3 1 LCV and SCV parameter LCV is used to set the limit for low credit event If the credit on prepaid SIM cards falls below this limit SMS is send SCV the period of valid operating time varies with different GSM network providers The value can be programmed from 1 to 360...
Страница 24: ... for the replays received from CC3 number Table of parameters Name Comment LCV Low credit value bottom limit for low credit event SCV Sim card validity time in days CC1 Credit number for credit check universally used CC2 Credit number for credit check dedicated for Italian TIM mobile provider CC3 Credit number for credit check dedicated for Italian Vodafone mobile provider CREF String for parsing ...
Страница 25: ...ion 0 value is used in order to conceal the telephone number of the ZEUS4 MC LITE device Value 1 means that the number is displayed 10 4 4 TST parameter A test SMS is sent periodically ZEUS4 MC LITE can send the test message in the interval ranging from 1 hour to 240 hours Example To send test SMS TST value is set to 12 the numbers linked to LN7 receive a test message every 12 hours 10 4 5 TSTT pa...
Страница 26: ...nt audio modes on ZEUS4 MC LITE device AUD 0 Optimized for voice data transfer AUD 1 Optimized for plain audio call 10 4 8 MIC1 parameter MIC1 parameter enables you to change the sound level on microphone Microphone level can be in range from 0 to 40 10 4 9 SPK parameter SPK parameter enables you to change the speaker sound level Speaker level can be in range from 0 to 20 10 4 10 RTN parameter RNT...
Страница 27: ...e multiple settings in one step Used for special purposes Contact sales for more information 10 4 16 ADF parameter Parameter is used to define voice refresh function to prevent blocking of SIM in some networks When ADF time out expires call is made to TN1 telephone number 10 4 17 SPO parameter SPO parameter is used to define the starting point for storage of ZEUS4 MC LITE parameters on SIM card NO...
Страница 28: ...system time synchronization HTN Hidden telephone number 1 displayed 0 hidden TST Periodic test SMS TSTT Periodic test SMS start time MNF Automatic network searching default AUD Audio modes MIC1 Sound input level 0 40 SPK Sound output level 0 20 RTN Ring time LOT Active connection time out ARST GSM module auto restart time LNG Switch between different languages LED Led indication control BIDI Multi...
Страница 29: ... LITE MNF 29340 Manual fixing of the GSM provider Simobil LNG 1 Switch to Italian language MIC1 15 Microphone sound level SPK 8 Speaker sound level TST 24 24 hours periodic test SMS TSTT 14 First SMS will be send out at 12 00 REG 60 GSM module will be restarted if ZEUS4 MC LITE is 60s out of the GSM registration Table 26 Set up parameters example Remote programming by SMS CRE 2 HTN 0 MNF 29340 LNG...
Страница 30: ...an vary in range from 0 to 20 10 5 3 COUT parameter COUT parameter is used to set outgoing volume level for CID communication COUT level can vary in range from 0 to 40 10 5 4 TN11 parameter TN11 parameter represents primary telephone number for CID reporting 10 5 5 TN12 parameter TN12 parameter represents secondary telephone number for CID reporting Table of parameters Name Comment CID CID functio...
Страница 31: ... SIM card ZEUS4 MC LITE PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description CID 1 CID reporting enabled CIN 12 CID incoming volume level TN11 042340880 Primary telephone number Table 28 CID parameters example Remote programming by SMS CID 1 CIN 12 TN11 042340880 ...
Страница 32: ...s an action in case when the LOG memory is FULL ALC 0 Automatically delete buffer when memory is FULL ALC 1 Memory buffer must be deleted manually when it is FULL Table of parameters Name Comment LOGI Log storage LOGN Number of log events for print ALC Control for memory handling in case memory storage is full Table 29 LOG parameters Example Direct programming on the SIM card ZEUS4 MC LITE PROGRAM...
Страница 33: ...el NOTE ZEUS4 MC LITE supports DTMF CLI representitation ETSI 10 7 3 GPR parameter ZEUS4 MC LITE is always checking the status of POST line interface connected Device will automatically divert to GSM interface if POTS line is lost In addition the user has the option to request this divert manually with the use one of the input on ZEUS4 MC LITE device Input is selected with the GPR parameter 10 7 4...
Страница 34: ...t number in PABX network DRC Control of DTMF support Table 31 Line interface parameters Example Direct programming on the SIM card ZEUS4 MC LITE PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description CID 1 CID reporting enabled CIN 12 CID incoming volume level TN11 042340880 Primary telephone number Table 32 Line interface parameters example Remote programming by SMS CID 1 CIN 12 TN11 04234...
Страница 35: ...E TELEPHONE NUMBERS PTN By sending this command to ZEUS4 MC LITE you receive SMS message with all currently programmed telephone numbers TN1 TN4 PTN 11 4 RECEIVE LINKS PLN By sending this command to ZEUS4 MC LITE you receive SMS message with all currently programmed links LN1 LN11 PLN 11 5 RECEIVE INPUT PARAMETERS PIN By sending this command to ZEUS4 MC LITE you receive SMS message with all curren...
Страница 36: ...TE you receive SMS message with all currently programmed credit check parameters CC1 CC2 and CC3 PCN 11 10 RECEIVE CREDIT CHECK PARSE STRING PARAMATERS PCREF By sending this command to ZEUS4 MC LITE you receive SMS message with all currently programmed credit parse string parameters CREF CTIM and CVODA PCREF 11 11 RECEIVE CREDIT STATUS FOR CC1 PCC1 By sending this command to ZEUS4 MC LITE you rece...
Страница 37: ...E LINK FOR LOCAL ALARM OUTPUT POD By sending this command to ZEUS4 MC LITE you receive SMS message with all currently programmed direct output alarm links OD1 OD11 POD 11 17 RECEIVE ALL PROGRAMMED SMS MESSAGES P By sending this command to ZEUS4 MC LITE you receive SMS message with all currently programmed alarm SMS messages 0 2 P 11 18 RECEIVE THE POWER LEVEL ON THE UNIT PPWR By sending this comma...
Страница 38: ... EVENTS PLOG By sending this command to ZEUS4 MC LITE you receive SMS messages with log parameters and log events PLOG NOTE When working with SMS use this parameter print with care It might generate lot of SMS messages in replay 11 23 STATE OF THE OUTPUTS PORC By sending this command to ZEUS4 MC LITE you receive SMS message with current outputs state PORC 11 24 STATE OF THE INPUTS INS By sending t...
Страница 39: ...l parameters and SMS on SIM card After delete process is completed the system will be restarted Now ZEUS4 MC LITE will be loaded with factory default settings SDCLR 12 2 GSM MODULE RESTART MRES MRES command is used to restart GSM module MRES 12 3 SYSTEM RESTART SSRES SSRES command is used to restart ZEUS4 MC LITE SSRES 12 4 LOG MEMORY CLEAR LCLR LCLR command is used to manually clear internal memo...
Страница 40: ...sage with state of the system SYS Return SMS can be SYS ON System is ON active inputs SYS OFF System is OFF inputs are not active 13 2 CHANGING SYSTEM STATUS TO ON SYSTEM ON By sending this command to ZEUS4 MC LITE it switches the system ON SYS 1 or SYS ON 13 3 CHANGING SYSTEM STATUS TO OFF SYSTEM OFF By sending this command to ZEUS4 MC LITE it switches the system OFF SYS 0 or SYS OFF ...
Страница 41: ... message is INS 1 4 OPEN ON alarm loop is open and the input is in alarm state INS 1 4 OPEN OFF alarm loop is open and the alarm input is in idle state INS 1 4 LOW ON alarm loop is close on GND and the input is in alarm state INS 1 4 LOW OFF alarm loop is close on the GND and the alarm input is in idle state INS 1 4 HGH ON alarm loop is close on 12MCC and the input is in alarm state INS 1 4 HIGH O...
Страница 42: ...tput status PORC Return SMS message is Output 1 ON OFF status on output 1 Output 2 ON OFF status on output 2 15 2 OUTPUT REMOTE CONTROL BY SMS COMMAND By sending this command to ZEUS4 MC LITE the output X is switched ON ORCx 1 or ORCx ON For x please choose one of the output numbers from 1 to 2 By sending this command to ZEUS4 MC LITE the output X is switched OFF ORCx 0 or ORCx OFF For x please ch...
Страница 43: ...0 TN3 0 TN4 0 If you would like to receive confirmation SMS write before SMS command TN1 38643364850 TN2 041255630 TN3 0 TN4 0 Return SMS from ZEUS4 MC is TN1 38643364850 TN2 041255630 TN3 0 TN4 0 NOTE You can use the same programming procedure for all parameters NOTE It is also possible to change different parameters with one SMS Consider that the SMS message should not be longer than 160 charact...
Страница 44: ...ease set these parameters LN1 123 TN1 040211411 TN2M 041211511 TN3 051334556 With these configuration alarm notification will be send to TN1 voice and SMS TN2 only SMS and TN3 only voice 17 2 CID EVENT REPORTING This example represents how to enable CID function for ZEUS4 MC LITE event reporting The data will be sending to 1 CMS CID 1 CIN 15 COUT 12 TN11 042340880 ...
Страница 45: ...r own GPRS TCP IP server or you can use provided server application for example Kronos NET The ZEUS4 MC LITE is used as simple control panel which is using for event reporting GPRS TCP IP connection In addition ZEUS4 MC LITE supports all events reporting functions beside that it can be used to transmit all events from the alarm control panel to the server The alarm control panel is connected to th...
Страница 46: ... alarm control panel Possible values 0 Event sending over GPRS TCP IP connection is disabled 1 Event sending over GPRS TCP IP connection is enabled 19 3 IPAPN This is an Access Point Name for GPRS TCP IP connection Example IPAPN internet simobil si setting for Si mobil Slovenia MCC MNC code 29340 NOTE If this parameter is not set the device will not try to initiate GPRS TCP IP connection 19 4 IPUS...
Страница 47: ... MC LITE reaches the connection and sends out events in the memory Example IPADD1 192 168 1 1 19 7 IPADD2 This is a secondary IP address of the GPRS TCP IP server Example IPADD2 192 168 1 2 NOTE At least one parameter must be set IPADD1 or IPADD2 for the device to try to initiate IP connection 19 8 IPPORT This is a port number on the TCP server NOTE If this parameter is not set the device will not...
Страница 48: ...19 12 IPPR This parameter is used so to select connection protocol for event reporting NOTE Contact your sales office for detail information about different options 19 13 IPCRE This parameter is used to define number of resending attempts in case of sending errors If value defined is reached all current events which were not send are skipped Possible values 0 resending limit is disabled 0 resendin...
Страница 49: ... GPRS TCP IP connection parameters To start enable GPRS TCP IP connection next parameter are USUALLY NEEDED Usually needed GPRS TCP IP settings IPUSR value Set appropriate GPRS user name IPPSW value Set appropriate GPRS password Table 34 Usually needed GPRS TCP IP connection parameters NOTE Device can t merge data from 2 consecutive SMS messages 20 2 EVENT REPORTING To enable event reporting over ...
Страница 50: ...anagement is possible To start GPRS TCP IP connection IPSTART SMS must be send and to finish management mode IPEND command must be send In addition there is a timeout installed in the application that disconnects the GPRS TCP IP management connection if it lasts more than 10 minutes When using IPSTART command the connection is made to server IPADD1 Management GPRS TCP IP setting IPSTART Start of t...
Страница 51: ...nerated on control panel connected to the ZEUS4 MC LITE device will be sending to the receiving server NOTE GPRS setting are used for Si Mobil Slovenia MCC MNC code 29340 For your test please use the GPRS setting from your GSM provider Use SMS to send this configuration to ZEUS4 MC LITE device IPAPN internet simobil si IPUSR simobil IPPSW internet IPADD1 193 77 158 153 IPORT 2020 0Objekt 1234 Afte...
Страница 52: ...e mode 90mA QUAD band GSM module 850 900 1800 1900 MHz PCB dimensions 105 80 mm Unit dimensions 118 170 60 mm Unit dimensions IP56 box 155 220 82 mm Antenna SMA 1 Weight without battery 500g Alarm inputs 2 GSM Priority input 1 Alarm outputs open collector 2 12V DC Power Supply input Y Backup battery input Y Telephone line interface Y No of alarm SMS per unit 2 Programmed telephone numbers 4 Anti t...
Страница 53: ... Input 2 link to tel numbers LN5 Empty Main power indication link to tel numbers LN6 Empty Battery power indication link to tel numbers LN7 Empty Periodic SMS link to tel numbers LN8 Empty SIM card validity and credits status link to tel numbers LN9 Empty System tamper link to tel numbers LN11 Empty LOG status link to tel numbers ID1 1 Input 1 delay filter on input ID2 1 Input 2 delay filter on in...
Страница 54: ...ct ID enable disable CIN 15 Contact ID input level 0 20 COUT 15 Contact ID output level 0 40 TN11 Empty Contact ID telephone number 1 TN12 Empty Contact ID telephone number 2 LOGN 5 Number of log events for printing out LOGI 0 Log storage place ALC 1 Automatic log clear ARST 0 Automatic reset timeout LED 1 Led function enable disable ADF 90 Auto dial function REG 30 Out of GSM registration CREF EU...
Страница 55: ...US4 MC LITE PROGRAMMING TABLE Name Default Value Short Description IPPR 0 Connection protocol for event reporting IPMOD 0 Connection mode IPCRE 0 Number of resending attempts in case of sending errors Table 37 ZEUS4 MC LITE default settings ...
Страница 56: ...e INSTALLATION MANUAL 52 24 CONTACTS MARS COMMERCE d o o MIRKA VADNOVA 19 SI 4000 KRANJ SLOVENIA TEL 386 4 280 74 00 E MAIL info mars commerce si WEB SITE www mars commerce com SALES E MAIL sales mars commerce com ...