PROGRAMMING GSW1
GSW1 device supports different types of programming:
(
You can program GSW1 remotely by SMS commands.
(
You can program GSW1 with direct USB connection, with the use of configuration software
running on PC (EasySet)
(
You can program GSW1 with SmartPhone App.
(
You can program GSW1 with Web Access (soon).
NOTE
To receive configuration software please contact your local distributor.
9
THE GSW1 PARAMETERS
To support versatile functionality of GSW1 different parameters are used. The parameters are
divided in logical sections and are described in the following chapters.
9.1 ALARM SUPPORT
Alarm reporting is supported by group of different parameters. First section is used to define the
relations needed for alarm to be trigged. The second section is used to report alarm.
9.1.1
ALARM TRIGGERING
Parameters are used to control (filter) the triggering of the alarm inputs.
9.1.1.1 IN parameters
Alarm and reset input can be triggered in 4 different ways. The status of the input can either be
normal closed (N.C) or normal open (N.O.) with positive (+ 12V) or negative (GND) voltage.
Activation of the input/alarm is reported by INx values 0 to 2. It the user needs to receive
information of the input/alarm restores use INx values 4 to 6. INx value 3 disables the input/alarm
reporting.
(
IN = 0
s
Normal Open
s
triggered with negative voltage (GND)
(
IN = 1
s
Normal Close
s
breaking negative or positive voltage loop
(
IN = 2
s
Normal Open
s
triggered with positive voltage (+ 12VCC)
(
IN = 3
s
Not in use
(
IN = 4 => IN = 0 + input reset SMS
(
IN = 5 => IN = 1 + input reset SMS
(
IN = 6 => IN = 2 + input reset SMS