• Permanently connected (Hard wired).
• Rated 240V, 60Hz, 50A, three wires (#6 copper) plus ground (#8 copper
(8.42mm
2
)), [4 wires total].
• Circuit breaker or fuse size: 50A.
• A disconnecting means must be installed within sight from the equipment
and at least 5 feet (1.52m) from the inside walls of the spa.
• Connect only to a circuit protected by a Class A ground Fault Circuit Inter-
rupter (GFCI).
120 Volt
120 Volt spas shall be plugged into a properly grounded, grounding type 15
amp receptacle on a dedicated circuit. A dedicated circuit is a circuit with no
other components that consume power, such as lights, televisions, radios,
computers, or other electronic devices. These could cause your spa to mal-
function by any of the following: unusual text on the control panel, slow heating,
poor jet action, tripping house breaker, or blown fuses. Failure to follow these
instructions could lead to premature failure of spa components that would not
be covered under the warranty. The dedicated circuit shall meet the following
specifications:
• Rated 120V, 60Hz, 15A (2 wires plus ground)
• Circuit breaker or fuse size: 15A
• The receptacle must be at least 5 feet (1.52 m) from the spa.
• The 15 foot GFCI power cord provided with the spa must be plugged
directly into the receptacle. Do NOT use an extension cord or any other
adaptor. Actual exposed length of cord will vary by model, but will never be
less than 12 feet.
INSTALLATION INSTRUCTIONS
TP (MAIN) PANELS
J34 OR J35
01-12-18
PART A
F4 3A SLO-BLOW
J25 J31
J26 J30
115V 115V
230V
F3 0.3A SLO-BLOW
J25=HTR1
J26=HTR2
J27=HTR3
J30=TEST
J31=CE
HTR
SEL
F7 10A 250VAC
F2 10A 250VAC
J44
3
TB1
J15
ON
10
S1
K5
K1
K3
T1
K2
K4
K8
LIGHT
GND
J33
J21
J32
J9
1
2
3
4
2
K6
4
3
2
1
J45
J110
J79
J54
J72
J42
J3
J37
J4
J1
J61
J47
J77 J75
J78
J36
J60
J46
J38
J39
J111
J53
J58
J11
J41
J48
J6
J7
J49
J19
J50
J13
J12
J88
J62
F6 30A
F8 30A
J56
J57
J55
J59
J51
J52
J98
J10
J81
J20
J18
J43
NOT USED
OZONE
A/V HOT
PUMP 1
J14
PUMP 2
K9
J5
AUX
J8
AUX
J40
REMOTE
J35
MAIN
J34
MAIN
J109
J27
J91
J22
J23
SERIAL
J29
VAC
J28
AUX
FRZ
J17
J16
24082_D
J101
J108
J24
J107
K12
K7
HTR
DISBL
AUX*
J5 (A1-A4)
OR
J8 (A5-A8)
GRN
WHT
RED
BLK
MQBP20UX – PN 56935
SENSOR B
SENSOR A
4.0 kW HEATER
LOCATION DEVICE
VOLTS
AMPS FROM
TO
FROM
TO
J1 ON RT 2 SPD
240V
12A
W1 ON
GROUP 2 J6 ON
GROUP 3
EXPANDER PUMP 3
MAX
EXPANDER J1
EXPANDER J53
SETUP 3 ONLY
J1
W1
J7
RIGHT
EXPANDER
BOARD
J6
EXPANDER
X-P332
F1 30A
SETUPS 4, 5, 9 & 10 ONLY
PUMP 3/MS
LOCATION DEVICE
VOLTS
AMPS FROM
TO
FROM
TO
J1 ON RT 1 SPD
240V
12A
W1 ON
GROUP 2 J6 ON
GROUP 3
EXPANDER
MICROSILK®
MAX
EXPANDER J1
EXPANDER J53
MICROSILK IS A REGISTERED TRADEMARK
OF JASON INTERNATIONAL
WiFi
Transceiver
J34 OR J35
IR Receiver
OR
RF Receiver
* AUX BUTTON FOR MICROSILK®
IS A3 PLUGGED INTO J5.
OPTIONAL
EXPANDER
BOARD #55137, ONLY
USED IN SETUPS 3.
4, 5, 9 & 10.
PART A
PASSED
DIELECTRIC
GROUND CONTINUITY
(FOR CORD-CONNECTED SPAS ONLY)
TESTED BY
DATE
12
Содержание V65L
Страница 16: ...THE V65L ZONES ZONE 1A N N N ZONE 1B N N N N N N ZONE 1C 16...
Страница 18: ...THE V77L 1 PUMP ZONES ZONE 1A N N N ZONE 1B N N N N N N ZONE 1C 18...
Страница 19: ...THE V77L 2 PUMP ZONES ZONE 1A N N N ZONE 1B N N N N N N ZONE 2 19...
Страница 21: ...THE V84 1 PUMP ZONES ZONE 1A ZONE 1B ZONE 1C 21...
Страница 22: ...THE V84 2 PUMP ZONES ZONE 2A ZONE 2B 22...
Страница 24: ...THE V84L 1 PUMP ZONES ZONE 1A ZONE 1B THE V84L 2 PUMP ZONES ZONE 2A ZONE 2B 24...