045%6.
Kit is required for a See Thru Installation.
%HIRUH\RXEHJLQ)UDPLQJ
- Determine whether the
:DOO6XUIDFH
will be flush with the face of the fireplace (Fireplace
and wall to be covered with Non-Combustibles, such as tile), or the
)UDPLQJ
will be flush
with the face of the fireplace (Flat Wall appearance).
1RWH
If using optional surround, maximum thickness for non-
combustible material is 3/4”.
&RQWLQXHG
)UDPHG2SHQLQJ´[´
Framing style shown is for illustration purposes only.
This structure is NOT load bearing.
[Steel Stud Framing Shown]
Fireplace vent MUST maintain min. 1” clearance from combustible (Wood) framing.
However, if steel stud framing is used, 1” vent clearance is not required.
$OVRUHIHUWRWKHVHVHFWLRQV
Clearance to Combustibles
Enclosure Heights
Venting
1RWH
If Combustible (Wood) Framing Studs
are used, they must be rotated to allow
Min.1” Clearance from Airbox.
1” Min Clearance Around All Sides of Airbox